HMH72B341
HMH7 · source records, page 32
784 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 784 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 784 / 784 |
| EER2 · BTU/Wh | 9–10.5 | 784 / 784 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 784 / 784 |
| Cooling capacity · BTU/h | 31,400–35,200 | 784 / 784 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 784 / 784 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 784 / 784 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 784 / 784 |
| COP at 5°F / −15°C | 1.8–2.18 | 784 / 784 |
| Equipment / loop type | HP - Split System | 784 / 784 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 784 / 784 |
| Compressor staging | Continuously variable | 784 / 784 |
| Connected capability | No | 784 / 784 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC48FXXN1+TXV+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 211394609 | 16.50 | 8.50 | 24200 | 2.10 | EPA 2481182 → |
XAHD48FBCN1+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 211394312 | 16.50 | 8.50 | 23200 | 2.06 | EPA 2481227 → |
XAHD48FXXN1+TXV+ furnace: TM9V120D20MP12Cold climate designationAHRI reference: 211394264 | 16.50 | 8.50 | 23200 | 2.06 | EPA 2481244 → |
XAHD48FXXN1+TXV+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 211394279 | 16.50 | 8.50 | 23200 | 2.06 | EPA 2481247 → |
XAHC48FXXN1+TXV+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 211386504 | 16.50 | 8.10 | 24200 | 2.04 | EPA 2482585 → |
XAHC48FBCN1+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 211386519 | 16.50 | 8.10 | 24200 | 2.04 | EPA 2482590 → |
XAFD48FBCN1+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 211386545 | 16.50 | 8.50 | 24000 | 2.08 | EPA 2482598 → |
XAFD48FXXN1+TXV+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 211386533 | 16.50 | 8.50 | 24000 | 2.08 | EPA 2482599 → |
XAFC48FXXN1+TXV+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 211386557 | 16.50 | 8.50 | 24600 | 2.08 | EPA 2482603 → |
XAHC36DBCN1+ furnace: TM9Y100C16MP11Cold climate designationAHRI reference: 211386725 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2482636 → |
XAHC36DXXN1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211386795 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2482645 → |
XAHC36DBCN1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211386811 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2482650 → |
XAHC36DXXN1+TXV+ furnace: TM9Y100C16MP11Cold climate designationAHRI reference: 211386714 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2482696 → |
XAFB36DXXN1+TXV+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387197 | 16.50 | 8.50 | 23600 | 2.04 | EPA 2482709 → |
XAHC48FXXN1+TXV+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211394194 | 16.50 | 8.10 | 23600 | 1.98 | EPA 2482848 → |
XAHC48FBCN1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211394209 | 16.50 | 8.10 | 23600 | 1.98 | EPA 2482851 → |
XAFC48FXXN1+TXV+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211394222 | 16.50 | 8.10 | 24000 | 2.02 | EPA 2482857 → |
XAFC48FBCN1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211394235 | 16.50 | 8.10 | 24000 | 2.02 | EPA 2482860 → |
XAFB36DBCN1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387211 | 16.50 | 8.50 | 23600 | 2.04 | EPA 2482932 → |
XAHD48FBCN1+ furnace: TM9Y120D20MP11Cold climate designationAHRI reference: 211393812 | 16.50 | 8.50 | 23400 | 2.04 | EPA 2482984 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →