Heating performance & equipment details
Ranges include the 784 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 784 / 784 |
| EER2 · BTU/Wh | 9–10.5 | 784 / 784 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 784 / 784 |
| Cooling capacity · BTU/h | 31,400–35,200 | 784 / 784 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 784 / 784 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 784 / 784 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 784 / 784 |
| COP at 5°F / −15°C | 1.8–2.18 | 784 / 784 |
| Equipment / loop type | HP - Split System | 784 / 784 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 784 / 784 |
| Compressor staging | Continuously variable | 784 / 784 |
| Connected capability | No | 784 / 784 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHB36DXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387743 | 16.50 | 8.10 | 23600 | 2.00 | EPA 2478239 → |
XAFD48FBCN1+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 211397657 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2478297 → |
XAFC48FBCN1+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211395895 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2478305 → |
XAHC48FBCN1+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 211397483 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2478472 → |
XAFC48FXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211395834 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2478621 → |
XAHC48FXXN1+TXV+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 211397394 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2478628 → |
XAHD48FXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211396056 | 16.50 | 8.10 | 24200 | 2.04 | EPA 2478657 → |
XAHD48FXXN1+TXV+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 211394398 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2478781 → |
XAHB36DXXN1+TXV+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 211390866 | 16.50 | 8.10 | 23800 | 2.02 | EPA 2478861 → |
XAHC48FBCN1+ furnace: TM8Y120C20MP11Cold climate designationAHRI reference: 211396554 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2479053 → |
XAHD48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398392 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2479063 → |
XAHC48FBCN1+ furnace: TM8Y100C20MP11Cold climate designationAHRI reference: 211396568 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2479069 → |
XAFC48FXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211395810 | 16.50 | 8.10 | 24000 | 2.04 | EPA 2479196 → |
XAHB36DBCN1+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387763 | 16.50 | 8.10 | 23600 | 2.00 | EPA 2479541 → |
XAHD48FBCN1+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211396071 | 16.50 | 8.10 | 24200 | 2.04 | EPA 2479713 → |
XAFD48FBCN1+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 211397642 | 16.50 | 8.50 | 24400 | 2.10 | EPA 2479915 → |
XAHC48FBCN1+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 211398838 | 16.50 | 8.50 | 23000 | 2.04 | EPA 2480033 → |
XAHD48FBCN1+ furnace: TM8E080C16MP11Cold climate designationAHRI reference: 211398773 | 16.50 | 8.50 | 23000 | 2.02 | EPA 2480039 → |
XAHC48FBCN1+ furnace: TM8E080C16MP11Cold climate designationAHRI reference: 211398823 | 16.50 | 8.50 | 23000 | 2.04 | EPA 2480366 → |
XAHD48FBCN1+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 211398787 | 16.50 | 8.50 | 23000 | 2.02 | EPA 2480368 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →