HMH72B341
HMH7 · source records, page 18
784 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 784 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 784 / 784 |
| EER2 · BTU/Wh | 9–10.5 | 784 / 784 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 784 / 784 |
| Cooling capacity · BTU/h | 31,400–35,200 | 784 / 784 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 784 / 784 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 784 / 784 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 784 / 784 |
| COP at 5°F / −15°C | 1.8–2.18 | 784 / 784 |
| Equipment / loop type | HP - Split System | 784 / 784 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 784 / 784 |
| Compressor staging | Continuously variable | 784 / 784 |
| Connected capability | No | 784 / 784 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC48FXXN1+TXV+ furnace: TM8E100C16MP11Cold climate designationAHRI reference: 211398514 | 17.00 | 8.50 | 23600 | 2.06 | EPA 2474668 → |
XAFD48FBCN1+ furnace: TM8E100C16MP11Cold climate designationAHRI reference: 211398485 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2474671 → |
XAFC48FXXN1+TXV+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398529 | 17.00 | 8.50 | 23600 | 2.06 | EPA 2474674 → |
XAFD48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398499 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2474700 → |
XAHD48FBCN1+ furnace: TM8Y100C16MP11Cold climate designationAHRI reference: 211396751 | 17.00 | 8.10 | 24000 | 2.04 | EPA 2474718 → |
XAHD48FBCN1+ furnace: TM8Y080C16MP11Cold climate designationAHRI reference: 211396766 | 17.00 | 8.10 | 24000 | 2.04 | EPA 2474838 → |
XAHB36DBCN1+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211388157 | 17.00 | 8.10 | 23400 | 1.98 | EPA 2474859 → |
XAFB36DBCN1+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 211390765 | 17.00 | 8.10 | 23600 | 2.02 | EPA 2474919 → |
XAFC36DBCN1+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 211390637 | 17.00 | 8.10 | 24200 | 2.04 | EPA 2475079 → |
XAFC48FBCN1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 211398716 | 17.00 | 8.50 | 23800 | 2.06 | EPA 2475116 → |
XAHC48FBCN1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 211396987 | 17.00 | 8.10 | 23000 | 2.02 | EPA 2475127 → |
XAFC48FXXN1+TXV+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 211398671 | 17.00 | 8.50 | 23800 | 2.06 | EPA 2476035 → |
XAFC36DXXN1+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 211390604 | 17.00 | 8.10 | 24200 | 2.04 | EPA 2476143 → |
XAFC48FXXN1+TXV+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211398656 | 17.00 | 8.50 | 23800 | 2.06 | EPA 2476160 → |
XAHC48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398451 | 17.00 | 8.50 | 23200 | 2.04 | EPA 2476189 → |
XAFD48FXXN1+TXV+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 211395984 | 17.00 | 8.50 | 23600 | 2.06 | EPA 2476323 → |
XAFC48FXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211396148 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2476338 → |
XAFC48FBCN1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211398686 | 17.00 | 8.50 | 23800 | 2.06 | EPA 2476401 → |
XAHC36DXXN1+TXV+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 211388944 | 17.00 | 8.10 | 23800 | 2.00 | EPA 2476421 → |
XAFB36DXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211388306 | 17.00 | 8.50 | 23800 | 2.04 | EPA 2476513 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.