HMH72B341
HMH7 · source records, page 11
784 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 784 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 784 / 784 |
| EER2 · BTU/Wh | 9–10.5 | 784 / 784 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 784 / 784 |
| Cooling capacity · BTU/h | 31,400–35,200 | 784 / 784 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 784 / 784 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 784 / 784 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 784 / 784 |
| COP at 5°F / −15°C | 1.8–2.18 | 784 / 784 |
| Equipment / loop type | HP - Split System | 784 / 784 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 784 / 784 |
| Compressor staging | Continuously variable | 784 / 784 |
| Connected capability | No | 784 / 784 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFB36DBCN1+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 211387020 | 17.50 | 8.50 | 23600 | 2.04 | EPA 2478782 → |
XAFB36DXXN1+TXV+ furnace: TMLV060A12MP12Cold climate designationAHRI reference: 211391014 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2478877 → |
XAHB36DBCN1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 211391700 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2478896 → |
XAFB36DXXN1+TXV+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 211389073 | 17.50 | 8.10 | 24200 | 2.04 | EPA 2479100 → |
XAHC36DBCN1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387088 | 17.50 | 8.10 | 23600 | 2.00 | EPA 2479210 → |
XAHB36DBCN1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211391693 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2479298 → |
XAFC36DXXN1+TXV+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 211387501 | 17.50 | 8.50 | 24000 | 2.10 | EPA 2479521 → |
XAFC36DBCN1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388847 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2479531 → |
XAFB36DBCN1+ furnace: TM9E060A10MP12Cold climate designationAHRI reference: 211389196 | 17.50 | 8.10 | 23800 | 2.02 | EPA 2480021 → |
XAHC36DBCN1+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 211392184 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2480086 → |
XAHC36DBCN1+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 211392168 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2480088 → |
XAFB36DXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387892 | 17.50 | 8.50 | 23400 | 2.04 | EPA 2480359 → |
XAFB36DBCN1+ furnace: TMLV060A12MP12Cold climate designationAHRI reference: 211391074 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2480433 → |
XAFC36DBCN1+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 211387336 | 17.50 | 8.10 | 24800 | 2.12 | EPA 2480664 → |
XAFC36DXXN1+TXV+ furnace: TL8E100C20UH11Cold climate designationAHRI reference: 211393358 | 17.50 | 8.50 | 24000 | 2.12 | EPA 2480884 → |
XAFC48FXXN1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394082 | 17.50 | 8.50 | 24200 | 2.06 | EPA 2480966 → |
XAFC48FBCN1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394097 | 17.50 | 8.50 | 24200 | 2.06 | EPA 2480981 → |
XAFD48FBCN1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394067 | 17.50 | 8.50 | 23600 | 2.06 | EPA 2481135 → |
XAFC36DXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211388226 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2481209 → |
XAFC36DBCN1+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 211389044 | 17.50 | 8.10 | 24200 | 2.04 | EPA 2481258 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →