Fraser-Johnston / AIR-SOURCE HEAT PUMP

HL19B2421

RELIANT · source records, page 3

61 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity21,200–24,000BTU/h

Each efficiency range summarizes published EPA records for HL19B2421. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 61 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1861 / 61
EER2 · BTU/Wh11.7–1461 / 61
HSPF2 · BTU/Wh7.861 / 61
Cooling capacity · BTU/h21,200–24,00061 / 61
Heating capacity at 47°F / 8.3°C · BTU/h22,400–23,80061 / 61
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,20061 / 61
Heating capacity at 5°F / −15°C · BTU/h10,900–12,20061 / 61
COP at 5°F / −15°C1.8–2.0661 / 61
Equipment / loop typeHP - Split System61 / 61
Refrigerant / source-reported GWPR-410A (GWP:2088)61 / 61
Compressor stagingTwo-stage61 / 61
Connected capabilityNo61 / 61

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFA30DBAN1+ furnace: Z8ES040A12LMPS1AHRI reference: 21248459517.007.80110001.80EPA 3990576
XAHB36DBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248879917.007.80109001.80EPA 3991097
XAHB36DBAN1+ furnace: TM9V060B12MP12AHRI reference: 20937000516.007.80112001.98EPA 2475949
XAHB36DBAN1+ furnace: TP9C080B12MP13AHRI reference: 20936998916.007.80110002.00EPA 2475950
XAHB36DBAN1+ furnace: TM9V080B12MP12AHRI reference: 20936998516.007.80110002.00EPA 2476699
XAHB36DBAN1+ furnace: TP9C060B12MP13AHRI reference: 20937000916.007.80112001.98EPA 2476709
XAHB36DBAN1+ furnace: TM9E026A08MP12AHRI reference: 20937002316.007.80111001.96EPA 2476715
XAHB36DBAN1+ furnace: TM8Y080B12MP11AHRI reference: 20937002716.007.80109002.02EPA 2476724
XAHB36DBAN1+ furnace: TM8V080B12MP12AHRI reference: 20937004416.007.80112001.98EPA 2476960
XAHB36DBAN1+ furnace: TL9E060B12UH11AHRI reference: 20937006516.007.80112002.00EPA 2477767
XAHB36DBAN1+ furnace: TM9E080B12MP12AHRI reference: 21029696616.007.80110001.98EPA 3984167
XAHB36DBAN1+ furnace: TM9Y060B12MP11AHRI reference: 21029629416.007.80110002.00EPA 3984344
XAHB36DBAN1+ furnace: TM9Y080B12MP11AHRI reference: 21029631816.007.80110002.00EPA 3984346
XAHB36DBAN1+ furnace: TM9E060B12MP12AHRI reference: 21029632616.007.80114001.98EPA 3984350
XAFA30DBAN1+ furnace: Z9ES026A08SMPS1AHRI reference: 21176910716.007.80112001.98EPA 3990236
XAFA30DBAN1+ furnace: Z9ES040A10SMPS1AHRI reference: 21176911116.007.80116002.00EPA 3990241
XAHB36DBAN1+ furnace: Z9ES060B12SMPS1AHRI reference: 21176911516.007.80120002.06EPA 3990242
XAFA30DBAN1+ furnace: Z9ES060A10SMPS1AHRI reference: 21176912516.007.80115002.02EPA 3990243
XAFB36DBAN1+ furnace: Z9ES060B12SMPS1AHRI reference: 21176911916.007.80116001.80EPA 3990247
XAFA30DBAN1+ furnace: Z9ET040A10SMPS1AHRI reference: 21176915116.007.80122002.00EPA 3990248

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.