Fraser-Johnston / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 10

372 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 372 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18372 / 372
EER2 · BTU/Wh11–12372 / 372
HSPF2 · BTU/Wh8.1–8.5372 / 372
Cooling capacity · BTU/h43,500–54,000372 / 372
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500372 / 372
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500372 / 372
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000372 / 372
COP at 5°F / −15°C2–2.32372 / 372
Equipment / loop typeHP - Split System372 / 372
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)372 / 372
Compressor stagingTwo-stage372 / 372
Connected capabilityNo372 / 372

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS1+TXV+ furnace: TM9E080C16MP12AHRI reference: 21870058817.508.10352002.20EPA 4686326 →
CTF60C5CGS1+ furnace: TM9E080C16MP12AHRI reference: 21870058417.508.10352002.20EPA 4686330 →
CTM60C5CGS1+ furnace: TPLC100C16MP13AHRI reference: 21870054017.508.10338002.20EPA 4686374 →
CTM60C5CGS1+ furnace: TPLC080C16MP13AHRI reference: 21870053617.508.10338002.20EPA 4686378 →
CTM60C5CGS1+ furnace: TMLV100C16MP12AHRI reference: 21870053217.508.10338002.20EPA 4686382 →
CTM60C5CGS1+ furnace: TM8V080C16MP12AHRI reference: 21870052817.508.10338002.20EPA 4686386 →
CTM60C5CGS1+ furnace: TM8V100C16MP12AHRI reference: 21870052417.508.10338002.20EPA 4686390 →
CTM60C5CGS1+ furnace: TM9E080C16MP12AHRI reference: 21870052017.508.10352002.20EPA 4686394 →
CTM60C5CGS1+ furnace: TL8E100C20UH11AHRI reference: 21870051617.508.10350002.26EPA 4686398 →
CTU60C5XGS1+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 21870051217.508.10350002.22EPA 4686402 →
CTF60C5CGS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21870050817.508.10350002.22EPA 4686406 →
CTU60C5XGS1+TXV+ furnace: TPLC120C20MP13AHRI reference: 21870049217.508.10340002.20EPA 4686422 →
CTU60C5XGS1+TXV+ furnace: TPLC100C20MP13AHRI reference: 21870048817.508.10340002.20EPA 4686426 →
CTU60C5XGS1+TXV+ furnace: TMLV120C20MP12AHRI reference: 21870048417.508.10340002.20EPA 4686430 →
CTU60C5XGS1+TXV+ furnace: TM8V100C20MP12AHRI reference: 21870048017.508.10340002.20EPA 4686434 →
CTU60C5XGS1+TXV+ furnace: TM8V120C20MP12AHRI reference: 21870047617.508.10340002.20EPA 4686438 →
CTF60C5CGS1+ furnace: TPLC120C20MP13AHRI reference: 21870046817.508.10340002.20EPA 4686446 →
CTF60C5CGS1+ furnace: TPLC100C20MP13AHRI reference: 21870046417.508.10340002.20EPA 4686450 →
CTF60C5CGS1+ furnace: TMLV120C20MP12AHRI reference: 21870046017.508.10340002.20EPA 4686454 →
CTF60C5CGS1+ furnace: TM8V100C20MP12AHRI reference: 21870045617.508.10340002.20EPA 4686458 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →