HH860E2S11
LX SERIES · source records, page 6
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: TMLV120C20MP12Cold climate designationAHRI reference: 214398044 | 19.00 | 9.00 | 39000 | 2.00 | EPA 3716528 → |
CTM60C5CHS1+ furnace: Z8ES080C20SMPS1Cold climate designationAHRI reference: 214594996 | 19.00 | 9.00 | 39000 | 2.00 | EPA 3716533 → |
CTF60D5CJS1+ furnace: Z8ES130D20SMPS1Cold climate designationAHRI reference: 214595011 | 19.00 | 9.00 | 39000 | 2.00 | EPA 3716539 → |
CTF60C5CHS1+ furnace: Z8ES080C20SMPS1Cold climate designationAHRI reference: 214595041 | 19.00 | 9.00 | 39000 | 2.00 | EPA 3716543 → |
CTM60C5CHS1+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 214609050 | 19.00 | 8.50 | 39000 | 2.00 | EPA 3716547 → |
CTF60C5CHS1+ furnace: Z9ES100C20SMPS1Cold climate designationAHRI reference: 214609079 | 19.00 | 8.50 | 38500 | 2.00 | EPA 3716552 → |
CTF60C5CHS1+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 214609162 | 19.00 | 8.50 | 39000 | 2.00 | EPA 3716559 → |
CTM60C5CHS1+ furnace: Z9ES100C20SMPS1Cold climate designationAHRI reference: 214609192 | 19.00 | 8.50 | 38500 | 2.00 | EPA 3716563 → |
CTU60D5XHS1+TXV+ furnace: TM9Y120D20MP11Cold climate designationAHRI reference: 214650388 | 19.00 | 8.50 | 39500 | 2.00 | EPA 3716568 → |
CTU60D5XHS1+TXV+ furnace: TM9V120D20MP12Cold climate designationAHRI reference: 214650499 | 19.00 | 9.00 | 39500 | 2.00 | EPA 3716573 → |
CTU60D5XHS1+TXV+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 214650520 | 19.00 | 9.00 | 39500 | 2.00 | EPA 3716578 → |
CTU60D5XHS1+TXV+ furnace: TM9E120D20MP12Cold climate designationAHRI reference: 214650725 | 19.00 | 8.50 | 39500 | 2.00 | EPA 3716585 → |
CTF60D5CJS1+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374739 | 19.00 | 9.00 | 40500 | 2.00 | EPA 3992100 → |
CTM60D5CJS1+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374780 | 19.00 | 9.00 | 40000 | 2.00 | EPA 3992102 → |
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 217444149 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4045087 → |
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 217444151 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4045088 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 217444152 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4045089 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 217444150 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4045090 → |
CTM60D5CHS1+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374576 | 19.00 | 8.50 | 40000 | 2.00 | EPA 4047622 → |
CTF60C5CGS1+ furnace: Z9ET100C16SMPS1Cold climate designationAHRI reference: 216374612 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4047653 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →