HH860E2S11
LX SERIES · source records, page 29
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS2+ furnace: TM9V080C16MP12AHRI reference: 218524184 | 17.00 | 9.00 | 33600 | 2.00 | EPA 4645725 → |
CTU60D5XHS1+TXVAHRI reference: 217334762 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4469657 → |
CTU60D5XGS1+TXVCold climate designationAHRI reference: 217334765 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4469658 → |
CTU60C5XGS1+TXVCold climate designationAHRI reference: 217334780 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4469666 → |
CTF60C5CGS1Cold climate designationAHRI reference: 214606549 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497285 → |
CTM60D5CGS1Cold climate designationAHRI reference: 214606551 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497286 → |
CTF60D5CHS1AHRI reference: 214606533 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497290 → |
CTF60C5CHS1AHRI reference: 214606537 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497293 → |
CTM60D5CHS1AHRI reference: 214606535 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497294 → |
CTM60C5CGS1Cold climate designationAHRI reference: 214606553 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497305 → |
CTM60C5CHS1AHRI reference: 214606554 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497313 → |
CTF60D5CGS1Cold climate designationAHRI reference: 214606568 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497323 → |
CTM60D5CJS1Cold climate designationAHRI reference: 214606527 | 15.20 | 8.50 | 40000 | 2.00 | EPA 4575832 → |
CTF60D5CJS1Cold climate designationAHRI reference: 214606526 | 15.20 | 8.50 | 40000 | 2.00 | EPA 4575833 → |
CTU60C5XGS2+TXVCold climate designationAHRI reference: 218581657 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649786 → |
CTF60D5CGS2Cold climate designationAHRI reference: 218581606 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649801 → |
CTM60C5CHS2AHRI reference: 218581576 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4649811 → |
CTM60C5CGS2Cold climate designationAHRI reference: 218581573 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649812 → |
CTM60D5CGS2Cold climate designationAHRI reference: 218581567 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649814 → |
CTF60C5CGS2Cold climate designationAHRI reference: 218581560 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649816 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →