HH860E2S11
LX SERIES · source records, page 12
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 218520790 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4644774 → |
CTM60C5CGS2+JMC17C2SN1AHRI reference: 218524626 | 19.00 | 9.00 | 33400 | 2.00 | EPA 4645283 → |
CTM60C5CGS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218524606 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645303 → |
CTM60C5CGS2+JMC16C2SN1AHRI reference: 218524588 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645321 → |
CTM60C5CGS2+JMVT16CC2N1AHRI reference: 218524584 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645325 → |
CTM60C5CGS2+JMVT17CC2N1AHRI reference: 218524560 | 19.00 | 9.50 | 33800 | 2.00 | EPA 4645349 → |
CTF60D5CGS2+JMVT20DC2N1AHRI reference: 218524528 | 19.00 | 9.50 | 33800 | 2.00 | EPA 4645381 → |
CTF60D5CGS2+JMC20D2SN1AHRI reference: 218524496 | 19.00 | 9.50 | 34000 | 2.00 | EPA 4645413 → |
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 218524432 | 19.00 | 9.00 | 32000 | 2.00 | EPA 4645477 → |
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218524428 | 19.00 | 9.00 | 32000 | 2.00 | EPA 4645481 → |
CTU60C5XGS2+JMC16C2SN1+TXVAHRI reference: 218524268 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645641 → |
CTF60C5CGS2+JMC16C2SN1AHRI reference: 218524264 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645645 → |
CTU60C5XGS2+JMVT16CC2N1+TXVAHRI reference: 218524172 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645737 → |
CTF60C5CGS2+JMVT16CC2N1AHRI reference: 218524168 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645741 → |
CTU60C5XGS2+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 218524108 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645801 → |
CTF60C5CGS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218524104 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645805 → |
CTF60D5CGS2+JME18D2SN2AHRI reference: 218637875 | 19.00 | 9.50 | 33800 | 2.00 | EPA 4663900 → |
CTM60C5CGS2+JME16C2SN2AHRI reference: 218637867 | 19.00 | 9.50 | 34000 | 2.00 | EPA 4663908 → |
CTU60C5XGS2+JME16C2SN2+TXVAHRI reference: 218637863 | 19.00 | 9.00 | 34200 | 2.00 | EPA 4663912 → |
CTF60C5CGS2+JME16C2SN2AHRI reference: 218637859 | 19.00 | 9.00 | 34200 | 2.00 | EPA 4663916 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →