HH836E2S11
LX SERIES · source records, page 40
863 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 863 / 863 |
| EER2 · BTU/Wh | 10–12 | 863 / 863 |
| HSPF2 · BTU/Wh | 8–9.5 | 863 / 863 |
| Cooling capacity · BTU/h | 31,600–35,000 | 863 / 863 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 863 / 863 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 863 / 863 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 863 / 863 |
| COP at 5°F / −15°C | 2–2.1 | 863 / 863 |
| Equipment / loop type | HP - Split System | 863 / 863 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 863 / 863 |
| Compressor staging | Continuously variable | 863 / 863 |
| Connected capability | No | 863 / 863 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF48C5CFS1+ furnace: TM9E080C20MP12Cold climate designationAHRI reference: 214397819 | 17.00 | 9.00 | 25400 | 2.00 | EPA 3714364 → |
CTM36B5CDS1+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 214398508 | 17.00 | 8.50 | 25000 | 2.00 | EPA 3714450 → |
CTM36B5CDS1+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 214398513 | 17.00 | 8.50 | 25000 | 2.00 | EPA 3714456 → |
CTF36C5CDS1+ furnace: TM9E100C20MP12Cold climate designationAHRI reference: 214398520 | 17.00 | 8.50 | 26800 | 2.00 | EPA 3714483 → |
CTF36C5CDS1+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 214398525 | 17.00 | 8.50 | 26200 | 2.00 | EPA 3714488 → |
CTM36C5CDS1+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 214398567 | 17.00 | 8.50 | 26200 | 2.00 | EPA 3714504 → |
CTU36B5XDS1+TXV+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 214728385 | 17.00 | 8.50 | 25400 | 2.00 | EPA 3714710 → |
CTU48C5XFS1+TXV+ furnace: TM9E100C20MP12Cold climate designationAHRI reference: 214719875 | 17.00 | 9.00 | 25800 | 2.00 | EPA 3714721 → |
CTU48C5XFS1+TXV+ furnace: TM9E080C20MP12Cold climate designationAHRI reference: 214720223 | 17.00 | 9.00 | 25400 | 2.00 | EPA 3714759 → |
CTU48C5XFS1+TXV+ furnace: TM9Y100C20MP11Cold climate designationAHRI reference: 214719907 | 17.00 | 8.50 | 26000 | 2.00 | EPA 3714866 → |
CTU36B5XDS1+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 214728373 | 17.00 | 8.50 | 25200 | 2.00 | EPA 3714982 → |
CTU36B5XDS1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 214728390 | 17.00 | 8.50 | 25200 | 2.00 | EPA 3715018 → |
CTU36B5XDS1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 214728395 | 17.00 | 8.50 | 25200 | 2.00 | EPA 3715022 → |
CTM36B5CDS1+ furnace: Z9ES060B12SMPS1Cold climate designationAHRI reference: 215853416 | 17.00 | 8.50 | 25400 | 2.00 | EPA 3715114 → |
CTF36B5CDS1+ furnace: Z9ES060B12SMPS1Cold climate designationAHRI reference: 215853417 | 17.00 | 8.50 | 25400 | 2.00 | EPA 3715115 → |
CTU36B5XDS1+TXV+ furnace: Z9ES060B12SMPS1Cold climate designationAHRI reference: 215853418 | 17.00 | 8.50 | 25400 | 2.00 | EPA 3715116 → |
CTF36C5CDS1+ furnace: Z9ES100C16SMPS1Cold climate designationAHRI reference: 215853424 | 17.00 | 8.50 | 27000 | 2.00 | EPA 3715122 → |
CTM36C5CDS1+ furnace: Z9ES100C16SMPS1Cold climate designationAHRI reference: 215853425 | 17.00 | 8.50 | 26800 | 2.00 | EPA 3715123 → |
CTF30A5ADS1+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 216508753 | 17.00 | 8.50 | 25200 | 2.00 | EPA 3848111 → |
CTF30A5ADS1+ furnace: TMLV060A12MP12Cold climate designationAHRI reference: 216508763 | 17.00 | 8.50 | 25200 | 2.00 | EPA 3848121 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →