SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19863 / 863
EER2 · BTU/Wh10–12863 / 863
HSPF2 · BTU/Wh8–9.5863 / 863
Cooling capacity · BTU/h31,600–35,000863 / 863
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400863 / 863
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600863 / 863
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200863 / 863
COP at 5°F / −15°C2–2.1863 / 863
Equipment / loop typeHP - Split System863 / 863
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)863 / 863
Compressor stagingContinuously variable863 / 863
Connected capabilityNo863 / 863

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5CDS2+ furnace: TP9C100C16MP13AHRI reference: 21852206018.008.50256002.00EPA 4643516 →
CTF36C5CDS2+ furnace: TM9V100C16MP12AHRI reference: 21852205618.008.50256002.00EPA 4643520 →
CTF36C5ADS2+ furnace: TP9C100C16MP13AHRI reference: 21852205018.008.50256002.00EPA 4643526 →
CTF36C5ADS2+ furnace: TM9V100C16MP12AHRI reference: 21852204618.008.50256002.00EPA 4643530 →
CTF36C5CDS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852204218.008.50262002.00EPA 4643534 →
CTF36C5CDS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852203818.008.50262002.00EPA 4643538 →
CTF36C5ADS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852203418.008.50262002.00EPA 4643542 →
CTF36C5ADS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852203018.008.50262002.00EPA 4643546 →
CTF36C5CDS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21852202618.008.50254002.00EPA 4643550 →
CTF36C5CDS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21852202218.008.50254002.00EPA 4643554 →
CTF36C5ADS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21852201818.008.50254002.00EPA 4643558 →
CTF36C5ADS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21852201418.008.50254002.00EPA 4643562 →
CTF36C5CDS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852201018.008.50260002.00EPA 4643566 →
CTF36C5CDS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852200618.008.50260002.00EPA 4643570 →
CTF36C5ADS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852200218.008.50260002.00EPA 4643574 →
CTF36C5ADS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852199818.008.50260002.00EPA 4643578 →
CTF36C5CDS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852199418.008.50264002.00EPA 4643582 →
CTF36C5ADS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852199018.008.50264002.00EPA 4643586 →
CTF36C5CDS2+ furnace: Z8ES100C20LMPS1AHRI reference: 21852198618.008.50262002.00EPA 4643590 →
CTF36C5CDS2+ furnace: Z8ES100C20SMPS1AHRI reference: 21852198218.008.50262002.00EPA 4643594 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.