Fraser-Johnston / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 2

863 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19863 / 863
EER2 · BTU/Wh10–12863 / 863
HSPF2 · BTU/Wh8–9.5863 / 863
Cooling capacity · BTU/h31,600–35,000863 / 863
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400863 / 863
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600863 / 863
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200863 / 863
COP at 5°F / −15°C2–2.1863 / 863
Equipment / loop typeHP - Split System863 / 863
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)863 / 863
Compressor stagingContinuously variable863 / 863
Connected capabilityNo863 / 863

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHE42C5CF2SS1Cold climate designationAHRI reference: 21439819319.009.00252002.00EPA 3437954
CTF48C5CFS1+JMC16C2SN1Cold climate designationAHRI reference: 21439820819.009.00252002.00EPA 3437960
CTM48C5CFS1+JMC16C2SN1Cold climate designationAHRI reference: 21439823319.009.00252002.00EPA 3437965
CTF48C5CFS1+JMVT16CC2N1Cold climate designationAHRI reference: 21439847319.009.00252002.00EPA 3438019
CTF36C5CDS1+JMVT16CC2N1Cold climate designationAHRI reference: 21439849819.009.00258002.00EPA 3438024
CTF48C5CFS1+JMVT17CC2N1Cold climate designationAHRI reference: 21439857219.009.00252002.00EPA 3438034
CTF48C5CFS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 21458462819.009.00252002.00EPA 3438141
CTM48C5CFS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 21458474819.009.00252002.00EPA 3438212
CTF36B5CDS1+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21458458819.009.00228002.00EPA 3438254
CTU48C5XFS1+TXV+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 21480777819.009.00252002.00EPA 3559299
CTU48C5XFS1+JMVT17CC2N1+TXVCold climate designationAHRI reference: 21480778319.009.00252002.00EPA 3559304
CTU48C5XFS1+JMC17C2SN1+TXVCold climate designationAHRI reference: 21480778819.009.00252002.00EPA 3559310
CTU48C5XFS1+JMVT16CC2N1+TXVCold climate designationAHRI reference: 21480779319.009.00252002.00EPA 3559313
CTU48C5XFS1+JME16C2SN1+TXVCold climate designationAHRI reference: 21480779819.009.00252002.00EPA 3559319
CTU36B5XDS1+JMVT12BC2N1+TXVCold climate designationAHRI reference: 21480774819.009.00256002.00EPA 3559569
CTU36B5XDS1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21480775319.009.00228002.00EPA 3559574
CTU36B5XDS1+JMC12B2SN1+TXVCold climate designationAHRI reference: 21480775819.009.00256002.00EPA 3559580
CTU36B5XDS1+JME12B2SN1+TXVCold climate designationAHRI reference: 21480776819.009.00248002.00EPA 3559589
CTM48C5CFS1+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 21439652519.009.00252002.00EPA 3713700
CTM48C5CFS1+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 21439653019.009.00252002.00EPA 3713707

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →