Fraser-Johnston / AIR-SOURCE HEAT PUMP

HH824E2S12

LX SERIES · source records, page 9

238 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 238 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18238 / 238
EER2 · BTU/Wh11–12238 / 238
HSPF2 · BTU/Wh8.1–8.5238 / 238
Cooling capacity · BTU/h22,400–24,000238 / 238
Heating capacity at 47°F / 8.3°C · BTU/h22,000–24,000238 / 238
Heating capacity at 17°F / −8.3°C · BTU/h20,600–22,800238 / 238
Heating capacity at 5°F / −15°C · BTU/h17,200–18,700238 / 238
COP at 5°F / −15°C2.22–2.46238 / 238
Equipment / loop typeHP - Split System238 / 238
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)238 / 238
Compressor stagingTwo-stage238 / 238
Connected capabilityNo238 / 238

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS2+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21869015816.508.50178002.26EPA 4679161
CTF30B5ACS2+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21869015616.508.50184002.28EPA 4679163
CTM30B5ACS2+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 21869015516.508.50180002.24EPA 4679164
CTM30B5ACS2+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21869015216.508.50178002.26EPA 4679167
CTU30B5XCS2+TXV+ furnace: TM9V060B12MP12AHRI reference: 21869012516.508.10174002.22EPA 4679189
CTF30B5ACS2+ furnace: TP9C060B12MP13AHRI reference: 21869012416.508.10174002.22EPA 4679190
CTU30B5XCS2+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 21869011816.508.50179002.26EPA 4679196
CTF30B5ACS2+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 21869011716.508.50179002.26EPA 4679197
CTF30B5ACS2+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21869011316.508.50178002.26EPA 4679201
CTM30B5ACS2+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 21869011016.508.50180002.24EPA 4679204
CTU36B5XDS1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21869861416.508.50184002.40EPA 4683906
CTF36B5ADS1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21869861016.508.50184002.40EPA 4683910
CTM36B5ADS1+ furnace: TPLC080B12MP13AHRI reference: 21869860416.508.10176002.28EPA 4683916
CTM36B5ADS1+ furnace: TM8V080B12MP12AHRI reference: 21869860016.508.10176002.28EPA 4683920
CTU30B5XCS1+TXV+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21869859616.508.50184002.28EPA 4683924
CTF30B5ACS1+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21869859216.508.50184002.28EPA 4683928
CTF30A5ADS1+ furnace: Z9ET040A10SMPS1AHRI reference: 21869858816.508.10176002.28EPA 4683932
CTF30A5ADS1+ furnace: TM9E026A08MP12AHRI reference: 21869857616.508.10181002.28EPA 4683944
CTU30B5XCS1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21869856016.508.50183002.30EPA 4683956
CTF30B5ACS1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21869855616.508.50183002.30EPA 4683960