Fraser-Johnston / AIR-SOURCE HEAT PUMP

HH824E2S11

LX SERIES · source records, page 6

318 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 318 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19318 / 318
EER2 · BTU/Wh11–12318 / 318
HSPF2 · BTU/Wh8.5–9.5318 / 318
Cooling capacity · BTU/h23,000318 / 318
Heating capacity at 47°F / 8.3°C · BTU/h23,000318 / 318
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,900318 / 318
Heating capacity at 5°F / −15°C · BTU/h17,200–19,400318 / 318
COP at 5°F / −15°C2318 / 318
Equipment / loop typeHP - Split System318 / 318
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)318 / 318
Compressor stagingContinuously variable318 / 318
Connected capabilityNo318 / 318

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU30B5XCS1+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21465163718.009.50191002.00EPA 3714830
CTU30B5XCS1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21465196918.009.50184002.00EPA 3714877
CTM30B5ACS1+JMET08BS2N1Cold climate designationAHRI reference: 21585330918.009.50181002.00EPA 3715173
CTM30B5ACS1+JMET12BS2N1Cold climate designationAHRI reference: 21585330818.009.50184002.00EPA 3715174
CTM30B5ACS1+JMVT12BC2N1Cold climate designationAHRI reference: 21585331018.009.50190002.00EPA 3715175
CTM36B5ADS1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 21591226018.009.50184002.00EPA 3723399
CTM36B5ADS1+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 21591224018.009.50185002.00EPA 3723413
CTM36B5ADS1+JMC12B2SN1Cold climate designationAHRI reference: 21601073718.009.50186002.00EPA 3737562
CTM36B5ADS1+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21601075218.009.00189002.00EPA 3737577
CTF36B5ADS1+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 21439622218.009.00185002.00EPA 3737807
CTF30A5ADS1+ furnace: Z9ES026A08SMPS1Cold climate designationAHRI reference: 21460909918.009.00181002.00EPA 3739078
CTF30A5ADS1+ furnace: Z9ES040A10SMPS1Cold climate designationAHRI reference: 21460907018.009.00177002.00EPA 3739115
CTF36B5ADS1+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 21460915818.009.50186002.00EPA 3739128
CTM36B5ADS1+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 21460918718.009.50186002.00EPA 3739135
CTU36B5XDS1+TXV+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21465007418.009.50189002.00EPA 3739158
CTU36B5XDS1+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 21465017718.009.00185002.00EPA 3739163
CTU36B5XDS1+TXV+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 21465022618.009.50186002.00EPA 3739238
CTU36B5XDS1+TXV+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 21465036718.009.50184002.00EPA 3739243
CTU36B5XDS1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21465070918.009.50188002.00EPA 3739258
CTU36B5XDS1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21465100118.009.50184002.00EPA 3739273

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →