198 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for 7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20198 / 198
EER2 · BTU/Wh11–13.2198 / 198
HSPF2 · BTU/Wh7.8–8.5198 / 198
Cooling capacity · BTU/h21,600–35,800198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h13,900–23,000198 / 198
Heating capacity at 5°F / −15°C · BTU/h12,100–17,700198 / 198
COP at 5°F / −15°C1.48–2.2198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)198 / 198
Compressor stagingContinuously variable198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH36CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21722232616.508.20163002.08EPA 4012557
7EH36CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21722232816.508.20163002.08EPA 4012559
7E[C,U]30BX-**+TDRAHRI reference: 21745573216.508.00144001.82EPA 4047510
7E[C,U]30AX-**+TDRAHRI reference: 21745578716.508.00144001.82EPA 4048320
7EH30BX-**+TDR+ furnace: 96G1UH045BE12*AHRI reference: 21746520516.508.20153001.88EPA 4469481
7EH30BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21746521716.508.50152001.88EPA 4469493
7ED30/36CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751299616.507.80165002.10EPA 4469760
7EH30BX-**+TDR+ furnace: 95G1UH040BE12X*AHRI reference: 21746519416.508.20153001.88EPA 4470237
7EH30BX-**+TDR+ furnace: 95G1UH060BE12X*AHRI reference: 21746519516.508.20153001.88EPA 4470241
7ED30/36CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867201716.507.80165002.10EPA 4673161
7EH36CX-**+TDR+ furnace: 97G1UH080CE16*AHRI reference: 21879195216.508.10173002.04EPA 4706687
7E[C,U]30/36BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21722231316.008.00163001.92EPA 4012543
7E[C,U]30/36BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 21722231216.008.00163001.92EPA 4012544
7E[C,U]30/36BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21722231516.008.00163001.92EPA 4012545
7E[C,U]30/36BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21722231416.008.00163001.92EPA 4012546
7E[C,U]30/36CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21722231616.008.00162001.94EPA 4012547
7E[C,U]30/36CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21722231716.008.10163001.92EPA 4012548
7EH36CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21722232116.008.10164002.08EPA 4012552
7EH36CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21722232216.008.10164002.08EPA 4012553
7ED30/36CX-**+TDR+ furnace: 97G2DF090CE16*AHRI reference: 21746512916.008.00164002.10EPA 4470132

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.