Ducane / AIR-SOURCE HEAT PUMP

7HP19V36P-**A

7HP19V SERIES · 7HP19V Series · A7HP19V Series · source records, page 8

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for 7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20198 / 198
EER2 · BTU/Wh11–13.2198 / 198
HSPF2 · BTU/Wh7.8–8.5198 / 198
Cooling capacity · BTU/h21,600–35,800198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h13,900–23,000198 / 198
Heating capacity at 5°F / −15°C · BTU/h12,100–17,700198 / 198
COP at 5°F / −15°C1.48–2.2198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)198 / 198
Compressor stagingContinuously variable198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-**+TDR+ furnace: 97G2UH070BE12*AHRI reference: 21746521617.008.50152001.88EPA 4469489
7EH30BX-**+TDR+ furnace: 97G2UH030BE08*AHRI reference: 21751300617.008.20150001.88EPA 4469766
7EH36CX-**+TDR+ furnace: 80G2UH110CV20*AHRI reference: 21751301017.008.10167002.06EPA 4469770
7EH36CX-**+TDR+ furnace: 97G2UH090CV12*AHRI reference: 21751301117.008.10165002.06EPA 4469771
7E[C,U]36BX-**+TDR*+ furnace: 80G2UH090BE16*AHRI reference: 21746444817.008.20148001.94EPA 4469953
7E[C,U]36BX-**+TDR*+ furnace: 80G2UH090BE16L*AHRI reference: 21746444417.008.20148001.94EPA 4469958
7EH30BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21746519817.008.50151001.90EPA 4470305
7EH30BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21746519917.008.50151001.90EPA 4470309
7E[C,U]36CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21832973617.008.20147001.94EPA 4584975
7E[C,U]36CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21832980717.008.20147001.94EPA 4585044
7EH30BX-**+TDR+ furnace: 97G1UH060BE12*AHRI reference: 21879188517.008.20153001.84EPA 4706660
7EH30BX-**+TDR+ furnace: 97G1UH030BE12*AHRI reference: 21879188217.008.10149001.80EPA 4706663
7EH36CX-**+TDR+ furnace: 97G1UH060BE12*AHRI reference: 21879187217.008.10170002.04EPA 4706666
7EH30BX-**+TDR+ furnace: EFV08BCA*AHRI reference: 21751300816.908.20154001.86EPA 4469767
7EH30BX-**+TDR+ furnace: EFV08BCP-**AHRI reference: 21867202116.908.20154001.86EPA 4673158
7AH1AC24PX-**AHRI reference: 21720242216.508.20156001.74EPA 4012182
7E[C,U]36BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21722230916.508.20148001.92EPA 4012540
7EH36CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21722232016.508.20161002.10EPA 4012551
7EH36CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21722232416.508.20162002.08EPA 4012555
7EH36CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21722232516.508.20162002.08EPA 4012556