Ducane / AIR-SOURCE HEAT PUMP

4HP17L42P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

67 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,000–42,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 67 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.667 / 67
EER2 · BTU/Wh12.5–1367 / 67
HSPF2 · BTU/Wh7.8–8.367 / 67
Cooling capacity · BTU/h40,000–42,00067 / 67
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,00067 / 67
Heating capacity at 17°F / −8.3°C · BTU/h25,000–27,60067 / 67
Heating capacity at 5°F / −15°C · BTU/h19,600–22,00067 / 67
COP at 5°F / −15°C2.02–2.267 / 67
Equipment / loop typeHP - Split System67 / 67
Refrigerant / source-reported GWPR-410A (GWP:2088)67 / 67
Compressor stagingSingle stage67 / 67
Connected capabilityNo67 / 67

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X49C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032489415.207.80199002.08EPA 2455455 →
EAC4X49C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21032489515.207.80199002.08EPA 2455560 →
BCE7E48M*4XAHRI reference: 21152112515.208.10200002.20EPA 2460645 →
EAC4X49C+TDR+ furnace: 92G1UH090CE16AHRI reference: 21032489915.207.80198002.08EPA 2460887 →
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH090CE16AHRI reference: 21032488915.207.80199002.08EPA 2461095 →
EAC4X49C+TDR+ furnace: 96G1UH090CE16AHRI reference: 21032490115.207.80199002.08EPA 2461400 →
EA(C;U)1P49C+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21032488215.207.80199002.08EPA 2461621 →
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21032488315.207.80199002.08EPA 2461864 →
EAD4X-48C+TDR+ furnace: 96G1DF110CE20AHRI reference: 21326507315.208.20220002.12EPA 2839852 →
7EC48CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471084915.207.80200002.08EPA 3484829 →
7EH48CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21471080315.207.80202002.04EPA 3484840 →
7EH48CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21471080415.207.80202002.04EPA 3484842 →
7EC48CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21471085315.207.80196002.06EPA 3484936 →
7EH48CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471079515.207.80202002.04EPA 3485128 →
7EH48CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471079615.207.80202002.04EPA 3485129 →
7ED48CX-0*+TDR+ furnace: 96G1DF110CE20AHRI reference: 21471081915.208.20220002.12EPA 3485156 →
7EC49CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21471086515.207.80199002.06EPA 3485214 →
7EC49CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21471086815.207.80199002.06EPA 3485216 →
7EH42BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471074015.207.80200002.06EPA 3485260 →
7EH48BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21471078515.207.80202002.02EPA 3485291 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →