Ducane / AIR-SOURCE HEAT PUMP

4HP17L42P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 2

67 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,000–42,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 67 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.667 / 67
EER2 · BTU/Wh12.5–1367 / 67
HSPF2 · BTU/Wh7.8–8.367 / 67
Cooling capacity · BTU/h40,000–42,00067 / 67
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,00067 / 67
Heating capacity at 17°F / −8.3°C · BTU/h25,000–27,60067 / 67
Heating capacity at 5°F / −15°C · BTU/h19,600–22,00067 / 67
COP at 5°F / −15°C2.02–2.267 / 67
Equipment / loop typeHP - Split System67 / 67
Refrigerant / source-reported GWPR-410A (GWP:2088)67 / 67
Compressor stagingSingle stage67 / 67
Connected capabilityNo67 / 67

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X49C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032489615.407.80199002.08EPA 2462395 →
EA(C;U)1P49C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032488415.407.80199002.08EPA 2462405 →
7EC48CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21471085015.407.80196002.10EPA 3484831 →
7EC48CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21471085115.407.80196002.10EPA 3484835 →
7EC48CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21471085415.407.80196002.10EPA 3484939 →
7EC48CX-0*+TDR+ furnace: 92G1UH110CE20AHRI reference: 21471085515.407.80199002.10EPA 3485055 →
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471074715.407.80202002.12EPA 3485070 →
7EC49CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471086215.407.80196002.08EPA 3485071 →
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471074815.407.80202002.12EPA 3485073 →
7EH42BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21471074915.407.80200002.12EPA 3485074 →
7EH42BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21471075015.407.80200002.12EPA 3485076 →
7EC49CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471086315.407.80199002.08EPA 3485213 →
7EC49CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471087015.407.80198002.12EPA 3485217 →
7EH42BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21471074115.407.80199002.10EPA 3485261 →
7EC49CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21471087115.407.80198002.10EPA 3485351 →
7EC49CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21471087215.407.80198002.10EPA 3485352 →
7EC49CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21471087515.407.80198002.10EPA 3485354 →
7EC49CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471086415.407.80199002.08EPA 3491644 →
7AH1AV42PX-0*AHRI reference: 21486576415.408.10202002.14EPA 3553891 →
EA(C;U)1P49C+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21032488715.207.80198002.08EPA 2455453 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →