Ducane / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 6

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471042715.807.80138002.00EPA 3485015
7EC36AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21471052115.808.00144002.26EPA 3485079
7EC36AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21471052215.808.00144002.26EPA 3485080
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21471049515.808.00141002.20EPA 3485088
7EH30BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21471044215.807.80136002.08EPA 3485105
7EH30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21471044515.808.00137002.08EPA 3485108
7EC30BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21471050215.808.10143002.24EPA 3485127
7EH30BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21471043615.807.80136002.08EPA 3485131
7EH36CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21471046315.808.30145002.20EPA 3485143
7EH30BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471043815.807.80138002.08EPA 3485162
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471050915.808.00144002.22EPA 3485171
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471051015.808.00144002.22EPA 3485173
7ED42BX-0*+TDR+ furnace: 80G2DF090BE16AHRI reference: 21471047915.808.60151002.32EPA 3485175
7ED42BX-0*+TDR+ furnace: 80G1DF070BE12AHRI reference: 21471048315.808.60153002.34EPA 3485180
7ED42BX-0*+TDR+ furnace: 92G1DF070BE12AHRI reference: 21471048615.808.60153002.32EPA 3485181
7ED42BX-0*+TDR+ furnace: 92G1DF045BE12AHRI reference: 21471048515.808.60153002.34EPA 3485182
7EH36CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471046815.808.50148002.26EPA 3485211
7EH30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21471045015.807.80138002.08EPA 3485225
7EH30BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21471045115.807.80136002.10EPA 3485227
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21471049415.808.00141002.20EPA 3485301

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.