Ducane / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 5

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032507215.808.10143002.24EPA 2460856 →
EAC4X30B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21032526615.808.00144002.22EPA 2460907 →
EAC4X30A+TDR+ furnace: 80G2UH045AE12AHRI reference: 21032523615.808.10143002.24EPA 2460909 →
EAC4X36A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032529215.808.10144002.26EPA 2460916 →
BCE7E30M*4XAHRI reference: 21032506315.808.50147002.36EPA 2461371 →
EAC4X30A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21032523015.808.00141002.20EPA 2461389 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032511115.808.00144002.26EPA 2461659 →
EAC4X36B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032531215.808.10142002.26EPA 2462145 →
EAH1P36C*+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21173612015.808.30147002.24EPA 2462797 →
BCE7S36M*4XAHRI reference: 21185560215.808.10149002.36EPA 2464142 →
EAH1P36C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173594215.808.30145002.22EPA 2467531 →
EAH1P30A*+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21173580515.807.80138002.00EPA 2468397 →
EAH1P36C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173605815.808.50148002.26EPA 2469287 →
EAD4X-42B+TDR+ furnace: 80G2DF090BE16AHRI reference: 21326504215.808.60151002.32EPA 2839605 →
EAD4X-42B+TDR+ furnace: 80G1DF070BE12AHRI reference: 21326504515.808.60153002.34EPA 2839608 →
EAD4X-42B+TDR+ furnace: 92G1DF045BE12AHRI reference: 21326504715.808.60153002.34EPA 2839612 →
EAD4X-42B+TDR+ furnace: 92G1DF070BE12AHRI reference: 21326504815.808.60153002.32EPA 2839648 →
7EH36CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21471047315.808.30147002.24EPA 3484925 →
7EC36AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21471053015.808.10144002.26EPA 3484961 →
7EC36BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471053415.808.10142002.26EPA 3484971 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →