Day & Night / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 11

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21563247516.508.10254002.22EPA 3952773
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21563248916.508.10258002.20EPA 3952788
EA*5X61M21A*+ furnace: *97CMN1002122B*AHRI reference: 21563260916.508.10260002.20EPA 3952964
EA*5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21563235016.508.10256002.22EPA 3953023
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 21563236316.508.10254002.22EPA 3953035
EA*5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 21563237916.508.10254002.22EPA 3953051
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21563239816.508.10252002.22EPA 3953069
EA*5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 21563252216.508.10256002.22EPA 3953108
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21563270616.508.10256002.22EPA 3953222
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21563284016.508.10256002.20EPA 3953394
EVM5X60M21A*+ furnace: *97CTN0802120A*AHRI reference: 21572203816.508.00252002.10EPA 3981682
EVM5X60M21A*+ furnace: *97VTN0802120A*AHRI reference: 21572206916.508.00248002.12EPA 3981711
EVM5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 21572208516.508.00246002.14EPA 3981730
EVD5X48M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572211316.508.00240002.14EPA 3981749
EVD5X48M21A*+ furnace: *97CTN1002122A*AHRI reference: 21572212716.508.10244002.15EPA 3981770
EVD5X48M21A*+ furnace: *97VTN1002120A*AHRI reference: 21572214416.508.00244002.12EPA 3981784
EVD5X49M24A*+ furnace: *97CTN1202422A*AHRI reference: 21572217216.508.00252002.10EPA 3981885
EVD5X60M21A*+ furnace: *80CSU0401712B*AHRI reference: 21572219916.508.00246002.14EPA 3981908
EVD5X60M21A*+ furnace: *80CSU1002120B*AHRI reference: 21572222716.508.00246002.14EPA 3981935
EA*5X61M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572184016.508.00252002.24EPA 3982258