N5H8T48*K*AAA*
2-STAGE 18 SEER HP · source records, page 10
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 215624991 | 16.50 | 8.10 | 24600 | 2.14 | EPA 3949129 → |
EVD5X60M21A*+ furnace: *80CTL0702120B*AHRI reference: 215624790 | 16.50 | 8.10 | 25600 | 2.06 | EPA 3949197 → |
EVD5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 215625102 | 16.50 | 8.10 | 25600 | 2.08 | EPA 3949314 → |
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 215625629 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3949403 → |
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 215625263 | 16.50 | 8.10 | 25200 | 2.10 | EPA 3949562 → |
EVD5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 215625531 | 16.50 | 8.10 | 25600 | 2.08 | EPA 3949651 → |
EVD5X61M24A*+ furnace: *97CMN1202422B*AHRI reference: 215625573 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3949677 → |
EVD5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 215625447 | 16.50 | 8.10 | 25600 | 2.10 | EPA 3949782 → |
EVD5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 215625678 | 16.50 | 8.10 | 25600 | 2.10 | EPA 3950006 → |
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 215625774 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3950169 → |
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 215628847 | 16.50 | 8.10 | 24200 | 2.14 | EPA 3950387 → |
EVD5X61M21A*+TDRAHRI reference: 215628704 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950478 → |
EVD5X61M24A*+TDRAHRI reference: 215628723 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950497 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215628834 | 16.50 | 8.10 | 25200 | 2.24 | EPA 3950512 → |
EVD5X60M21A*+TDRAHRI reference: 215628666 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950633 → |
EVM5X49M21A*+TDRAHRI reference: 215628533 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950771 → |
EVM5X60M21A*+TDRAHRI reference: 215628552 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950794 → |
EVM5X61M24A*+TDRAHRI reference: 215628590 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950828 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 215631864 | 16.50 | 8.10 | 25600 | 2.20 | EPA 3952582 → |
EA*5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 215632417 | 16.50 | 8.10 | 25800 | 2.22 | EPA 3952729 → |