Concord / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 5

257 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17257 / 257
EER2 · BTU/Wh12.5–14257 / 257
HSPF2 · BTU/Wh7.8–8.2257 / 257
Cooling capacity · BTU/h22,400–24,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700257 / 257
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500257 / 257
COP at 5°F / −15°C2–2.18257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471127616.407.80102002.06EPA 3485705
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 21032648616.408.00104002.06EPA 3984526
EAC4X24B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21032654516.407.80104002.04EPA 3984528
EAC4X24A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21032653716.207.80104002.02EPA 2471011
EAC4X24A+TDR+ furnace: 80G1UH070AE12AHRI reference: 21032653616.207.80104002.02EPA 2471014
BCE7E24M*4XAHRI reference: 21032642816.208.10104002.12EPA 2471370
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21032647116.207.80106002.04EPA 2471470
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21032645916.207.80102002.02EPA 2471471
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032646016.207.80104002.04EPA 2471569
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21032646916.207.80102002.00EPA 2471574
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032646116.207.80104002.04EPA 2471664
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032643116.207.80104002.02EPA 2471670
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21173500516.207.80106002.08EPA 2471704
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032643216.207.80104002.02EPA 2471767
EAH1P24A*+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21173496616.207.80102002.04EPA 2471939
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032643916.207.80104002.04EPA 2471996
EAD4X-30/36B+TDR+ furnace: 80G1DF090BE16AHRI reference: 21326511416.208.20112002.12EPA 2648907
EAD4X-30/36C+TDR+ furnace: 92G1DF090CE16AHRI reference: 21326512116.208.20110002.08EPA 2648929
EAC4X24A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032654416.207.80104002.04EPA 2836732
EAC4X30B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032657616.207.80106002.04EPA 2836741

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →