Concord / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 4

257 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17257 / 257
EER2 · BTU/Wh12.5–14257 / 257
HSPF2 · BTU/Wh7.8–8.2257 / 257
Cooling capacity · BTU/h22,400–24,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700257 / 257
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500257 / 257
COP at 5°F / −15°C2–2.18257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21471121716.407.80102002.04EPA 3485326
7EH24AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21471118816.407.80104002.06EPA 3485329
7EH24AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21471118916.407.80104002.06EPA 3485331
7EC24AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471124316.407.80102002.04EPA 3485397
7ED30/36CX-0*+TDR+ furnace: 96G1DF090CE16AHRI reference: 21471123816.408.20112002.10EPA 3485516
7EC30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21471129416.407.80104002.06EPA 3485543
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471129516.407.80104002.06EPA 3485544
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471129616.407.80104002.06EPA 3485547
7EC24BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471126316.407.80104002.04EPA 3485587
7EC24BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21471126416.407.80104002.08EPA 3485589
7EC24BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21471126516.407.80104002.08EPA 3485590
7EH30AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21471119716.408.00102002.08EPA 3485595
7EH30AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21471119816.408.00102002.08EPA 3485597
7EH30AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21471119916.408.00104002.14EPA 3485599
7EH30AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21471120016.408.00104002.14EPA 3485600
7EH30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21471120116.408.10106002.12EPA 3485602
7EH24AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471118316.407.80102002.04EPA 3485612
7EC24BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21471125616.407.80104002.04EPA 3485651
7EC24BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21471125716.407.80104002.04EPA 3485653
7EH30BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21471120316.407.80106002.02EPA 3485656

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.