Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X36M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217941919 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4556072 → |
EVD5X36M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217941874 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556109 → |
EVM5X32M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217937753 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556121 → |
EVM5X32M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217937769 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556186 → |
EVM5X32M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217937784 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556201 → |
EVD5X36M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217942452 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4556221 → |
EVD5X36M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217942377 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556232 → |
EVD5X31M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217941191 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4556257 → |
EVD5X36M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217941404 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556326 → |
EVD5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217941419 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556342 → |
EVD5X36M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217941434 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556356 → |
EVD5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217941449 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556371 → |
EVM5X31M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217937147 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556388 → |
EVM5X31M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217937163 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556398 → |
EVM5X31M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217937179 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4556415 → |
EVD5X37M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217942950 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556438 → |
EVD5X37M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217942965 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556465 → |
EVD5X37M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217943010 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556472 → |
EVM5X31M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217937482 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4556494 → |
EVM5X31M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217937497 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4556509 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.