Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 16
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X31M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217937389 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555509 → |
EVM5X32M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217937979 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555591 → |
EVM5X32M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217938025 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555637 → |
EVM5X30M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217936634 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555702 → |
EVD5X31M17A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 217941206 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4555785 → |
EVD5X31M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217941222 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4555800 → |
EVD5X36M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217942106 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4555834 → |
EVD5X36M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217942347 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4555847 → |
EVD5X36M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217942497 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4555858 → |
EVD5X36M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217942362 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4555865 → |
EVD5X25M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217939918 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555896 → |
EVD5X38M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217944058 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4555923 → |
EVM5X32M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217937799 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555940 → |
EVD5X36M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217942076 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4555960 → |
EVD5X36M21A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217942197 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4555974 → |
EVD5X36M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217942091 | 19.00 | 8.50 | 21000 | 1.90 | EPA 4555980 → |
EVM5X30M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217936769 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4555990 → |
EVM5X30M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217936799 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556020 → |
EVD5X38M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217944088 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4556034 → |
EVD5X38M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217944103 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4556055 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.