| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217947407 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4560920 → |
EA*5X37M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217944926 | 18.50 | 10.00 | 21000 | 2.00 | EPA 4561165 → |
EA*5X37M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217949129 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4561307 → |
EA*5X37M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217949144 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4561703 → |
EA*5X37M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217951099 | 18.50 | 10.00 | 21200 | 1.95 | EPA 4561735 → |
EA*5X37M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217951114 | 18.50 | 10.00 | 21000 | 1.95 | EPA 4561749 → |
EA*5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217951129 | 18.50 | 10.00 | 21200 | 1.95 | EPA 4561869 → |
EA*5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217951144 | 18.50 | 10.00 | 21200 | 1.95 | EPA 4561884 → |
EA*5X25M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217946595 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4561917 → |
EA*5X37M21A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217946655 | 18.50 | 10.00 | 21200 | 1.96 | EPA 4561928 → |
EA*5X25M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217947302 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4562195 → |
EA*5X25M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217947317 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4562210 → |
EA*5X25M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217947332 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4562225 → |
EA*5X25M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217947347 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4562240 → |
EA*5X37M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217946415 | 18.50 | 10.00 | 21000 | 1.95 | EPA 4562484 → |
EA*5X25M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217949063 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4562644 → |
EA*5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217949084 | 18.50 | 9.50 | 21200 | 1.92 | EPA 4562656 → |
EA*5X37M21A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217950709 | 18.50 | 10.00 | 21400 | 2.00 | EPA 4562730 → |
EA*5X37M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217945572 | 18.50 | 10.00 | 21200 | 1.96 | EPA 4563171 → |
EA*5X37M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217945602 | 18.50 | 10.00 | 21200 | 1.96 | EPA 4563201 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →