Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X25M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217946610 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4558751 → |
FTMA5B36L0C*Cold climate designationAHRI reference: 217950377 | 18.50 | 10.00 | 21200 | 2.02 | EPA 4558830 → |
EA*5X25M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217950392 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4558844 → |
EA*5X37M21A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217950407 | 18.50 | 10.00 | 21200 | 1.95 | EPA 4558862 → |
EA*5X37M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217950422 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4558872 → |
EA*5X25M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217948204 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4559022 → |
EA*5X37M21A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217946640 | 18.50 | 10.00 | 21200 | 1.95 | EPA 4559091 → |
EA*5X37M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217948220 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4559262 → |
EA*5X37M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217948235 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4559278 → |
EA*5X25M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217949010 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4559767 → |
EA*5X25M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217949036 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4559782 → |
EA*5X37M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217949099 | 18.50 | 9.50 | 21200 | 1.95 | EPA 4559794 → |
EA*5X37M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217949114 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4559810 → |
EA*5X25M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217949807 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4560132 → |
EA*5X25M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217949792 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4560456 → |
EA*5X25M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217951084 | 18.50 | 10.00 | 21200 | 1.96 | EPA 4560556 → |
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217948311 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4560766 → |
EA*5X25M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217947362 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4560876 → |
EA*5X37M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217947377 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4560887 → |
EA*5X37M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217947392 | 18.50 | 9.50 | 21200 | 1.90 | EPA 4560905 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.