Comfortmaker / AIR-SOURCE HEAT PUMP

C5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 12

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X36M17A*+ furnace: *97VTN0601716A*AHRI reference: 21636597317.008.00110002.06EPA 3812433 →
EA*5X36M17A*+ furnace: *97VTN0801716A*AHRI reference: 21636598317.008.00109002.06EPA 3812441 →
EA*5X37M21A*+ furnace: *96VTN0401712B*AHRI reference: 21636672317.008.10114002.08EPA 3812473 →
EA*5X37M21A*+ furnace: OLV098A12*AHRI reference: 21636677117.008.10115002.06EPA 3812521 →
EA*5X24M17A*+WALLCON+ furnace: *96CTN0801714B*AHRI reference: 21636477017.008.00110002.04EPA 3812561 →
ESH5X36M12A*+ furnace: *80VSL1102122B*AHRI reference: 21636831717.007.80110002.04EPA 3812618 →
ESH5X36M12A*+ furnace: *80MSU0802120A*AHRI reference: 21636834917.007.80110002.04EPA 3812650 →
EA*5X30M14A*+ furnace: *80VSL0451412B*AHRI reference: 21636521817.008.10109002.08EPA 3812660 →
EA*5X30M14A*+ furnace: *80VSL0701412B*AHRI reference: 21636522617.007.80109002.02EPA 3812667 →
EA*5X30M17A*+WALLCON+ furnace: *80CSU0601716A*AHRI reference: 21636529817.008.00109002.06EPA 3812697 →
EA*5X30M17A*+ furnace: *80VSL0451412B*AHRI reference: 21636530617.008.10109002.08EPA 3812705 →
EA*5X30M17A*+ furnace: *80VSL0701412B*AHRI reference: 21636531417.008.10109002.10EPA 3812713 →
EA*5X37M17A*+ furnace: OMV112K14AAHRI reference: 21636633117.008.10115002.08EPA 3812721 →
EA*5X37M17A*+WALLCON+ furnace: *97CTN0601716A*AHRI reference: 21636635517.008.00113002.06EPA 3812745 →
EA*5X37M17A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 21636636317.008.00113002.06EPA 3812753 →
EA*5X37M17A*+ furnace: *97VTN0601716A*AHRI reference: 21636637117.008.00111002.08EPA 3812761 →
EA*5X37M17A*+ furnace: *97VTN0801716A*AHRI reference: 21636637917.008.00111002.08EPA 3812769 →
ESH5X36M12A*+ furnace: *95MSU1002120A*AHRI reference: 21636862117.007.80110002.04EPA 3812869 →
ESH5X36M12A*+ furnace: *95MSU1002122A*AHRI reference: 21636862917.007.80110002.04EPA 3812877 →
EA*5X30M17A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 21636557817.008.00109002.06EPA 3812920 →