C5H8T24*K*AAA*
Mainline 18 SEER2 HP · source records, page 11
498 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 498 / 498 |
| EER2 · BTU/Wh | 11.7–14 | 498 / 498 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 498 / 498 |
| Cooling capacity · BTU/h | 22,200–25,000 | 498 / 498 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–25,400 | 498 / 498 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,100–15,000 | 498 / 498 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,700–11,500 | 498 / 498 |
| COP at 5°F / −15°C | 1.94–2.24 | 498 / 498 |
| Equipment / loop type | HP - Split System | 498 / 498 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 498 / 498 |
| Compressor staging | Two-stage | 498 / 498 |
| Connected capability | No | 498 / 498 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X30M17A*+ furnace: OMV112K14AAHRI reference: 216365562 | 17.00 | 8.10 | 11200 | 2.04 | EPA 3811393 → |
EA*5X30M17A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 216365570 | 17.00 | 8.00 | 10900 | 2.06 | EPA 3811401 → |
EA*5X36M17A*+ furnace: *80VSL0901716B*AHRI reference: 216365658 | 17.00 | 8.10 | 10900 | 2.10 | EPA 3811519 → |
EA*5X36M17A*+WALLCON+ furnace: *80CTL0451712B*AHRI reference: 216365682 | 17.00 | 8.00 | 11100 | 2.04 | EPA 3811543 → |
EA*5X36M17A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 216365690 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3811552 → |
EA*5X36M17A*+WALLCON+ furnace: *80CTL0701716B*AHRI reference: 216365698 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3811559 → |
EA*5X25M17A*+ furnace: *96VSN0601412B*AHRI reference: 216365042 | 17.00 | 8.10 | 11200 | 2.10 | EPA 3811670 → |
EA*5X30M14A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 216365234 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3811684 → |
EA*5X30M14A*+ furnace: *80VTL0451412B*AHRI reference: 216365242 | 17.00 | 8.10 | 10900 | 2.08 | EPA 3811692 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 216368781 | 17.00 | 8.00 | 11000 | 2.08 | EPA 3811783 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 216368789 | 17.00 | 8.00 | 11100 | 2.08 | EPA 3811805 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 216368797 | 17.00 | 8.00 | 11000 | 2.08 | EPA 3811813 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 216368253 | 17.00 | 8.00 | 11100 | 2.08 | EPA 3811967 → |
EA*5X24M14A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 216364506 | 17.00 | 8.00 | 11000 | 2.04 | EPA 3812001 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0601716A*AHRI reference: 216368261 | 17.00 | 8.00 | 11100 | 2.06 | EPA 3812036 → |
EA*5X36M17A*+ furnace: *96VTN0801716B*AHRI reference: 216365894 | 17.00 | 8.10 | 10900 | 2.08 | EPA 3812232 → |
EA*5X36M17A*+ furnace: OMV112K14AAHRI reference: 216365924 | 17.00 | 7.80 | 11200 | 1.98 | EPA 3812257 → |
EA*5X25M17A*+WALLCON+ furnace: *97CTN0601716A*AHRI reference: 216365186 | 17.00 | 8.00 | 11300 | 2.06 | EPA 3812309 → |
EA*5X36M17A*+ furnace: *96VTN0601716B*AHRI reference: 216365884 | 17.00 | 8.10 | 11000 | 2.08 | EPA 3812361 → |
EA*5X36M17A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 216365963 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3812425 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →