B5H0V48*K*AAA*
SoftSound 20 VS Heat Pump · source records, page 16
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218173667 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4581536 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218173658 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4581545 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218173655 | 16.50 | 8.50 | 33800 | 2.06 | EPA 4581548 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218173131 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4597784 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218173128 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4597787 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218173122 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4597790 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218173119 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4597793 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173116 | 16.50 | 8.50 | 33800 | 2.06 | EPA 4597796 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218173107 | 16.50 | 8.50 | 33600 | 2.06 | EPA 4597805 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218173104 | 16.50 | 8.50 | 33800 | 2.06 | EPA 4597808 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218173098 | 16.50 | 8.50 | 33600 | 2.06 | EPA 4597814 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218173095 | 16.50 | 8.50 | 33600 | 2.06 | EPA 4597817 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218173092 | 16.50 | 8.50 | 33600 | 2.06 | EPA 4597820 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218173089 | 16.50 | 8.50 | 34000 | 2.06 | EPA 4597823 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218173086 | 16.50 | 8.50 | 33800 | 2.06 | EPA 4597826 → |
ESH5X60M12A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218173670 | 16.00 | 8.50 | 34200 | 1.94 | EPA 4581533 → |
ESH5X48M12A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218173643 | 16.00 | 8.50 | 34800 | 1.92 | EPA 4581551 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218173634 | 16.00 | 8.50 | 34400 | 2.04 | EPA 4581554 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218173113 | 16.00 | 8.50 | 34200 | 1.94 | EPA 4597799 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218173110 | 16.00 | 8.50 | 34200 | 1.96 | EPA 4597802 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →