Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218172906 | 17.50 | 9.00 | 34000 | 2.04 | EPA 4597976 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218172900 | 17.50 | 9.00 | 34000 | 2.04 | EPA 4597979 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218172897 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4597982 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218172888 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4597991 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218172876 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4598003 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218172873 | 17.50 | 9.00 | 34200 | 2.06 | EPA 4598006 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218172870 | 17.50 | 9.00 | 34400 | 2.04 | EPA 4598009 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218173558 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4580880 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218173555 | 17.00 | 9.00 | 34000 | 2.04 | EPA 4580883 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218173549 | 17.00 | 9.00 | 34200 | 2.04 | EPA 4580889 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218173664 | 17.00 | 8.50 | 33600 | 2.06 | EPA 4581539 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218173661 | 17.00 | 8.50 | 33800 | 2.08 | EPA 4581542 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218172945 | 17.00 | 9.00 | 34600 | 2.06 | EPA 4597937 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218172894 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4597985 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218172891 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4597988 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218172885 | 17.00 | 9.00 | 34600 | 2.04 | EPA 4597994 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218172867 | 17.00 | 9.00 | 35000 | 2.02 | EPA 4598012 → |
ESH5X60M12A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218173679 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4581524 → |
ESH5X60M12A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218173676 | 16.50 | 8.50 | 33800 | 2.08 | EPA 4581527 → |
ESH5X60M12A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218173673 | 16.50 | 8.50 | 33800 | 2.06 | EPA 4581530 → |