Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1530S1R-**A

HRG15 SERIES · HRG15 Series · source records, page 3

78 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for HRG1530S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.278 / 78
EER2 · BTU/Wh12.5–13.578 / 78
HSPF2 · BTU/Wh7.8–8.678 / 78
Cooling capacity · BTU/h28,200–30,00078 / 78
Heating capacity at 47°F / 8.3°C · BTU/h27,200–30,00078 / 78
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,60078 / 78
Heating capacity at 5°F / −15°C · BTU/h13,400–15,40078 / 78
COP at 5°F / −15°C1.96–2.3478 / 78
Equipment / loop typeHP - Split System78 / 78
Refrigerant / source-reported GWPR-410A (GWP:2088)78 / 78
Compressor stagingSingle stage78 / 78
Connected capabilityNo78 / 78

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36A+TDR+TXV+ furnace: GUH96C070B3MAHRI reference: 21033044615.608.10143002.26EPA 2456290
EA(C;U)1P36A+TDR+TXV+ furnace: GUH96C045B3MAHRI reference: 21033044515.608.10146002.26EPA 2457109
EA(C;U)1P30A+TDR+TXV+ furnace: GUH92C070B3MAHRI reference: 21033043315.608.00144002.20EPA 2459146
EA(C;U)1P30A+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 21033043915.608.00145002.18EPA 2459412
EA(C;U)1P30A+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 21033043215.608.00144002.20EPA 2459427
EAD4X-42B+TDR+ furnace: GDD96C070B4MAHRI reference: 21326548415.608.60153002.32EPA 2839972
7EC30BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471296515.608.00144002.20EPA 3486538
7EC30BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471296615.608.00144002.20EPA 3486541
7EC30BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471296915.608.00145002.18EPA 3486550
7EH30BX-0*+TDR+ furnace: GUH96C045B3MAHRI reference: 21471293515.607.80138002.06EPA 3486938
7EH30BX-0*+TDR+ furnace: GUH96C070B3MAHRI reference: 21471293615.607.80138002.06EPA 3486940
7EC36BX-0*+TDR+ furnace: GUH80X080B4MAHRI reference: 21471297615.608.10146002.24EPA 3486978
7EH36CX-0*+TDR+ furnace: GUH80C110C5MAHRI reference: 21471294015.608.30146002.22EPA 3486983
7EH36CX-0*+TDR+ furnace: GUH92C090C4MAHRI reference: 21471294215.608.30146002.24EPA 3486984
7EH36CX-0*+TDR+ furnace: GUH92C090C3MAHRI reference: 21471294115.608.30147002.24EPA 3486986
7EH36CX-0*+TDR+ furnace: GUH96C090C4MAHRI reference: 21471294515.608.30145002.22EPA 3486989
7EH36CX-0*+TDR+ furnace: GUH96C110C5MAHRI reference: 21471294615.608.50148002.26EPA 3487023
7EH36CX-0*+TDR+ furnace: GUH97M090C3MAHRI reference: 21471294715.608.30147002.22EPA 3487026
7EH36CX-0*+TDR+ furnace: GUH97M090C4MAHRI reference: 21471294815.608.30144002.22EPA 3487027
7ED42BX-0*+TDR+ furnace: GDD96C070B4MAHRI reference: 21471295715.608.60153002.32EPA 3487037

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.