Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1530S1R-**A

HRG15 SERIES · HRG15 Series · source records, page 2

78 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for HRG1530S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.278 / 78
EER2 · BTU/Wh12.5–13.578 / 78
HSPF2 · BTU/Wh7.8–8.678 / 78
Cooling capacity · BTU/h28,200–30,00078 / 78
Heating capacity at 47°F / 8.3°C · BTU/h27,200–30,00078 / 78
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,60078 / 78
Heating capacity at 5°F / −15°C · BTU/h13,400–15,40078 / 78
COP at 5°F / −15°C1.96–2.3478 / 78
Equipment / loop typeHP - Split System78 / 78
Refrigerant / source-reported GWPR-410A (GWP:2088)78 / 78
Compressor stagingSingle stage78 / 78
Connected capabilityNo78 / 78

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36A+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 21033044315.808.10143002.26EPA 2456192
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 21033043615.808.00144002.22EPA 2456561
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 21033042915.808.00141002.20EPA 2456564
EAD4X-42B+TDR+ furnace: GDD80C070B3MAHRI reference: 21326547915.808.60153002.34EPA 2839862
EAD4X-42B+TDR+ furnace: GDD92C045B3MAHRI reference: 21326548115.808.60153002.34EPA 2839863
EAD4X-42B+TDR+ furnace: GDD92C070B3MAHRI reference: 21326548215.808.60153002.32EPA 2839971
7EC30BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471296315.808.00144002.22EPA 3486533
7EH30BX-0*+TDR+ furnace: GUH80X080B4MAHRI reference: 21471293015.807.80136002.08EPA 3486930
7EH30BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471293315.807.80136002.10EPA 3486937
7EH30BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471293715.808.00137002.08EPA 3486941
7EC36AX-0*+TDR+ furnace: GUH80X040A3MAHRI reference: 21471297115.808.00144002.26EPA 3486973
7EC36AX-0*+TDR+ furnace: GUH80X060A3MAHRI reference: 21471297215.808.00144002.26EPA 3486974
7EH36CX-0*+TDR+ furnace: GUH80C090C5MAHRI reference: 21471293915.808.50148002.26EPA 3486982
7EH36CX-0*+TDR+ furnace: GUH92C110C4MAHRI reference: 21471294315.808.30147002.24EPA 3486987
7ED42BX-0*+TDR+ furnace: GDD80C070B3MAHRI reference: 21471295215.808.60153002.34EPA 3487030
7ED42BX-0*+TDR+ furnace: GDD92C045B3MAHRI reference: 21471295415.808.60153002.34EPA 3487033
7ED42BX-0*+TDR+ furnace: GDD92C070B3MAHRI reference: 21471295515.808.60153002.32EPA 3487034
7EC30AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 21471296015.808.00141002.20EPA 3487041
7EC36BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471297915.808.10143002.26EPA 3487111
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 21033043015.608.00144002.20EPA 2456284

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →