Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1524S1R-**A

HRG15 Series · HRG17 SERIES · source records, page 2

79 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–23,800BTU/h

Each efficiency range summarizes published EPA records for HRG1524S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 79 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–1779 / 79
EER2 · BTU/Wh12.5–1479 / 79
HSPF2 · BTU/Wh7.8–8.279 / 79
Cooling capacity · BTU/h22,600–23,80079 / 79
Heating capacity at 47°F / 8.3°C · BTU/h21,200–22,60079 / 79
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,70079 / 79
Heating capacity at 5°F / −15°C · BTU/h10,200–11,50079 / 79
COP at 5°F / −15°C2–2.1479 / 79
Equipment / loop typeHP - Split System79 / 79
Refrigerant / source-reported GWPR-410A (GWP:2088)79 / 79
Compressor stagingSingle stage79 / 79
Connected capabilityNo79 / 79

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471292416.407.80104002.06EPA 3486860 →
7EH30AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 21471287616.408.00102002.08EPA 3486870 →
7EH24AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 21471287216.407.80104002.06EPA 3491871 →
EAD4X-30/36B+TDR+ furnace: GDD80C090B4MAHRI reference: 21326547116.208.20112002.12EPA 2648837 →
EAD4X-30/36C+TDR+ furnace: GDD92C090C4MAHRI reference: 21326547716.208.20110002.08EPA 2648856 →
EAH1P24A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 21033049816.207.80102002.04EPA 2765506 →
EAH1P30B+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 21033050216.207.80106002.06EPA 2765572 →
EA(C;U)1P24A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 21033047516.207.80104002.02EPA 2836962 →
EA(C;U)1P30A+TDR+TXV+ furnace: GUH92C070B3MAHRI reference: 21033049016.207.80106002.04EPA 2837091 →
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 21033048716.207.80104002.04EPA 2837104 →
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 21033048616.207.80102002.02EPA 2837228 →
7EH30BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471288216.207.80106002.06EPA 3486338 →
7ED30/36BX-0*+TDR+ furnace: GDD80C090B4MAHRI reference: 21471288816.208.20112002.12EPA 3486537 →
7EC24AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 21471290116.207.80104002.02EPA 3486604 →
7ED30/36CX-0*+TDR+ furnace: GDD92C090C4MAHRI reference: 21471289416.208.20110002.08EPA 3486639 →
7EC30AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 21471291416.207.80102002.02EPA 3486777 →
7EC30AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 21471291516.207.80104002.04EPA 3486811 →
7EC30BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471292116.207.80106002.04EPA 3486848 →
7EH24AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 21471287116.207.80102002.04EPA 3486867 →
HCG30V1PAHRI reference: 21185565416.008.10104002.06EPA 2471025 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →