Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1524S1R-**A

HRG15 Series · HRG17 SERIES

79 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–23,800BTU/h

Each efficiency range summarizes published EPA records for HRG1524S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 79 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–1779 / 79
EER2 · BTU/Wh12.5–1479 / 79
HSPF2 · BTU/Wh7.8–8.279 / 79
Cooling capacity · BTU/h22,600–23,80079 / 79
Heating capacity at 47°F / 8.3°C · BTU/h21,200–22,60079 / 79
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,70079 / 79
Heating capacity at 5°F / −15°C · BTU/h10,200–11,50079 / 79
COP at 5°F / −15°C2–2.1479 / 79
Equipment / loop typeHP - Split System79 / 79
Refrigerant / source-reported GWPR-410A (GWP:2088)79 / 79
Compressor stagingSingle stage79 / 79
Connected capabilityNo79 / 79

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-0*+TDR+ furnace: GUH80C090B4MAHRI reference: 21471288117.008.00104002.10EPA 3486335
7EH30BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471288016.808.00104002.06EPA 3486334
7EH30BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471288616.807.80104002.08EPA 3486891
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C090B4MAHRI reference: 21033049616.608.00104002.06EPA 2837166
7EH30BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471288316.608.00106002.06EPA 3486342
7EC30BX-0*+TDR+ furnace: GUH80C090B4MAHRI reference: 21471291916.608.00104002.06EPA 3486841
EAD4X-30/36C+TDR+ furnace: GDD96C090C4MAHRI reference: 21326547816.408.20112002.10EPA 2648857
EAH1P24A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 21033049716.407.80104002.06EPA 2765514
EA(C;U)1P24A+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 21033048416.407.80104002.04EPA 2836916
EA(C;U)1P24A+TDR+TXV+ furnace: GUH80C090B4MAHRI reference: 21033048516.407.80104002.08EPA 2837037
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 21033048816.407.80104002.06EPA 2837074
EA(C;U)1P24A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 21033047716.407.80104002.04EPA 2837127
EA(C;U)1P30A+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 21033049516.407.80104002.06EPA 2837164
7EH30AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 21471287716.408.00104002.14EPA 3486229
7EH30BX-0*+TDR+ furnace: GUH80X080B4MAHRI reference: 21471287916.407.80106002.02EPA 3486308
7EC24BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471290416.407.80104002.04EPA 3486618
7ED30/36CX-0*+TDR+ furnace: GDD96C090C4MAHRI reference: 21471289516.408.20112002.10EPA 3486640
7EC24BX-0*+TDR+ furnace: GUH80C090B4MAHRI reference: 21471290516.407.80104002.08EPA 3486732
7EC24BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471291016.407.80104002.04EPA 3486764
7EC30BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471291816.407.80104002.06EPA 3486836

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →