SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for HRG1518S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.871 / 71
EER2 · BTU/Wh12.5–1471 / 71
HSPF2 · BTU/Wh7.8–8.571 / 71
Cooling capacity · BTU/h18,00071 / 71
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,00071 / 71
Heating capacity at 17°F / −8.3°C · BTU/h10,200–11,80071 / 71
Heating capacity at 5°F / −15°C · BTU/h7,500–9,30071 / 71
COP at 5°F / −15°C1.92–2.1471 / 71
Equipment / loop typeHP - Split System71 / 71
Refrigerant / source-reported GWPR-410A (GWP:2088)71 / 71
Compressor stagingSingle stage71 / 71
Connected capabilityNo71 / 71

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30A+TDR+TXV+ furnace: GUH96C070B3MAHRI reference: 21042105416.407.8077001.98EPA 2457122 →
EA(C;U)1P24A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 21042104016.408.0082002.10EPA 2459636 →
EA(C;U)1P24A+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 21042104716.408.1084002.08EPA 2459638 →
EAD4X-30/36B+TDR+ furnace: GDD96C045B3MAHRI reference: 21326546616.408.3087002.10EPA 2839892 →
7EC24BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471285316.408.1084002.08EPA 3486349 →
7EC30AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 21471285816.407.8077001.98EPA 3486408 →
7EC24BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471284716.408.0082002.10EPA 3486481 →
7EH24BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471282216.408.1084002.10EPA 3486508 →
7EH24AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 21471281316.408.0080002.06EPA 3486632 →
7EH24AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 21471281416.408.0080002.04EPA 3486633 →
7EH24BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471281616.408.1082002.10EPA 3486634 →
7EH24BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471281816.408.1082002.08EPA 3486635 →
7EH24BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471281916.408.1082002.10EPA 3486636 →
7EC24AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 21471284516.408.0082002.10EPA 3486646 →
7EH30BX-0*+TDR+ furnace: GUH96C045B3MAHRI reference: 21471282916.407.8077001.98EPA 3486661 →
7EH30BX-0*+TDR+ furnace: GUH96C070B3MAHRI reference: 21471283016.407.8077002.00EPA 3486663 →
7ED30/36BX-0*+TDR+ furnace: GDD96C045B3MAHRI reference: 21471283616.408.3087002.10EPA 3486677 →
7EC30BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471286316.407.8076001.98EPA 3486788 →
7EC30BX-0*+TDR+ furnace: GUH96C045B3MAHRI reference: 21471286516.407.8077001.98EPA 3486790 →
7EC30BX-0*+TDR+ furnace: GUH96C070B3MAHRI reference: 21471286616.407.8077001.98EPA 3486792 →