Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1518S1R-**A

HRG15 SERIES · HRG15 Series

71 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for HRG1518S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.871 / 71
EER2 · BTU/Wh12.5–1471 / 71
HSPF2 · BTU/Wh7.8–8.571 / 71
Cooling capacity · BTU/h18,00071 / 71
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,00071 / 71
Heating capacity at 17°F / −8.3°C · BTU/h10,200–11,80071 / 71
Heating capacity at 5°F / −15°C · BTU/h7,500–9,30071 / 71
COP at 5°F / −15°C1.92–2.1471 / 71
Equipment / loop typeHP - Split System71 / 71
Refrigerant / source-reported GWPR-410A (GWP:2088)71 / 71
Compressor stagingSingle stage71 / 71
Connected capabilityNo71 / 71

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 21042105116.807.8077002.00EPA 2456449
EA(C;U)1P30A+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 21042105916.808.0078002.00EPA 2457311
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 21042105216.807.8077001.98EPA 2459679
7EC30AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 21471285716.807.8077002.00EPA 3486405
7EH30BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471282516.808.0077002.04EPA 3486517
7EH30BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471282716.808.0079002.02EPA 3486561
7EH30BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471282816.808.0076002.00EPA 3486563
7EH30BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471283116.808.0078002.00EPA 3486665
7EC30BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471286116.807.8077001.98EPA 3486786
7EC30BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471286716.808.0078002.00EPA 3486793
EA(C;U)1P30A+TDR+TXV+ furnace: GUH92C070B3MAHRI reference: 21042105616.607.8077002.02EPA 2456067
EAD4X-30/36B+TDR+ furnace: GDD92C045B3MAHRI reference: 21326546416.608.4089002.10EPA 2839995
EAD4X-30/36B+TDR+ furnace: GDD92C070B3MAHRI reference: 21326546516.608.5089002.10EPA 2839996
7ED30/36BX-0*+TDR+ furnace: GDD92C045B3MAHRI reference: 21471283416.608.4089002.10EPA 3486671
7ED30/36BX-0*+TDR+ furnace: GDD92C070B3MAHRI reference: 21471283516.608.5089002.10EPA 3486675
7EC30BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471286416.607.8077002.02EPA 3486789
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 21042105016.407.8077001.98EPA 2456260
EA(C;U)1P30A+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 21042105516.407.8076001.98EPA 2456347
EA(C;U)1P24A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 21042103816.408.0082002.10EPA 2456357
EA(C;U)1P30A+TDR+TXV+ furnace: GUH96C045B3MAHRI reference: 21042105316.407.8077001.98EPA 2456439

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →