Coleman / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 5

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS1+JMC16C2SN1+TXVAHRI reference: 21701913716.008.10272002.28EPA 4014317
CTF60D5CHS1+JMET18DS2N1AHRI reference: 21701913916.008.10268002.36EPA 4014319
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 21701914116.008.10268002.36EPA 4014321
CTF60D5CHS1+JMC20D2SN1AHRI reference: 21701914316.008.10270002.38EPA 4014323
CTU60D5XHS1+JMC20D2SN1+TXVAHRI reference: 21701914516.008.10270002.38EPA 4014325
CTF60D5CHS1+JME18D2SN1AHRI reference: 21701914716.008.10268002.38EPA 4014327
CTU60C5XGS1+JMC17C2SN1+TXVAHRI reference: 21701921316.008.10272002.28EPA 4014347
CTF60C5CGS1+JMVT16CC2N1AHRI reference: 21701921516.008.10272002.28EPA 4014349
CTU60C5XGS1+JMVT16CC2N1+TXVAHRI reference: 21701921716.008.10272002.28EPA 4014351
CTF60C5CHS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21701922916.008.10268002.34EPA 4014357
CTF60C5CGS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21701923116.008.10270002.26EPA 4014359
CTU60C5XGS1+TXV+ furnace: Z8ES080C16SMPS1AHRI reference: 21701923316.008.10270002.26EPA 4014361
CTM60C5CHS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21701923516.008.10266002.34EPA 4014363
CTF60C5CGS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701923716.008.10274002.22EPA 4014365
CTU60C5XGS1+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 21701923916.008.10274002.22EPA 4014367
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701924116.008.10272002.30EPA 4014369
CTF60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701924316.008.10276002.28EPA 4014371
CTF60C5CGS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21701924516.008.10274002.22EPA 4014373
CTU60C5XGS1+TXV+ furnace: Z9ET100C20SMPS1AHRI reference: 21701924716.008.10274002.22EPA 4014375
CTF60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21701924916.008.10276002.30EPA 4014377

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →