Coleman / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 4

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21701933616.008.10274002.32EPA 4014253 →
CTF60C5CGS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21701933816.008.10276002.26EPA 4014255 →
CTM60C5CHS1+JMVT16CC2N1AHRI reference: 21701910016.008.10270002.36EPA 4014289 →
CTU60D5XGS1+JMVT20DC2N1+TXVAHRI reference: 21701910116.008.10272002.30EPA 4014290 →
CTF60C5CHS1+JMET16CS2N1AHRI reference: 21701910216.008.10270002.34EPA 4014291 →
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 21701910316.008.10270002.38EPA 4014292 →
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 21701910416.008.10270002.38EPA 4014293 →
JHE60C5CH2SS1AHRI reference: 21701910516.008.10272002.34EPA 4014294 →
CTF60C5CHS1+JMC17C2SN1AHRI reference: 21701910616.008.10270002.36EPA 4014295 →
CTM60C5CHS1+JMC17C2SN1AHRI reference: 21701910716.008.10266002.36EPA 4014296 →
CTF60C5CHS1+JMVT17CC2N1AHRI reference: 21701910816.008.10270002.36EPA 4014297 →
CTF60C5CHS1+JMC16C2SN1AHRI reference: 21701910916.008.10270002.36EPA 4014298 →
JHC60D5CH2SS1AHRI reference: 21701911316.008.10270002.40EPA 4014299 →
CTM60C5CHS1+JMET16CS2N1AHRI reference: 21701911516.008.10270002.34EPA 4014301 →
CTM60C5CHS1+JME16C2SN1AHRI reference: 21701911716.008.10268002.36EPA 4014303 →
CTM60D5CHS1+JMC20D2SN1AHRI reference: 21701912316.008.10270002.38EPA 4014306 →
CTF60D5CGS1+JMET18DS2N1AHRI reference: 21701912516.008.10272002.28EPA 4014307 →
CTU60D5XGS1+JMET18DS2N1+TXVAHRI reference: 21701912716.008.10272002.28EPA 4014309 →
CTF60D5CGS1+JMVT20DC2N1AHRI reference: 21701912916.008.10272002.30EPA 4014311 →
CTF60C5CGS1+JMC16C2SN1AHRI reference: 21701913516.008.10272002.28EPA 4014315 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →