Coleman / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 2

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS1+JMET12CS2N1AHRI reference: 21701919516.008.10268002.26EPA 4014161
CTU60C5XGS1+JMET12CS2N1+TXVAHRI reference: 21701919716.008.10268002.26EPA 4014164
CTF60D5CGS1+JME18D2SN1AHRI reference: 21701919916.008.10270002.30EPA 4014166
CTU60D5XGS1+JME18D2SN1+TXVAHRI reference: 21701920116.008.10270002.30EPA 4014168
CTF60C5CHS1+JME12C2SN1AHRI reference: 21701920316.008.10264002.36EPA 4014170
CTF60C5CHS1+JME16C2SN1AHRI reference: 21701920516.008.10268002.36EPA 4014172
CTF60C5CHS1+JMET12CS2N1AHRI reference: 21701920716.008.10264002.34EPA 4014174
CTM60D5CHS1+JMET18DS2N1AHRI reference: 21701920916.008.10268002.36EPA 4014176
CTF60C5CGS1+JMC17C2SN1AHRI reference: 21701921116.008.10272002.28EPA 4014178
JHE48C5CG2SS1AHRI reference: 21701673916.008.00272002.10EPA 4014185
CTF60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21701927716.008.10274002.34EPA 4014199
CTF60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21701927916.008.10274002.34EPA 4014200
CTF60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21701928116.008.10272002.26EPA 4014202
CTU60C5XGS1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 21701928316.008.10272002.26EPA 4014203
CTM60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21701928516.008.10270002.36EPA 4014205
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701928716.008.10272002.34EPA 4014207
CTF60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701928916.008.10272002.34EPA 4014209
CTF60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701929116.008.10274002.26EPA 4014210
CTU60C5XGS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21701929316.008.10274002.26EPA 4014214
CTM60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21701929516.008.10274002.32EPA 4014215