XH648E2S11
LX SERIES · source records, page 2
554 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 554 / 554 |
| EER2 · BTU/Wh | 11.7–12 | 554 / 554 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 554 / 554 |
| Cooling capacity · BTU/h | 45,000–49,000 | 554 / 554 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 554 / 554 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 554 / 554 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 554 / 554 |
| COP at 5°F / −15°C | 2–2.4 | 554 / 554 |
| Equipment / loop type | HP - Split System | 554 / 554 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 554 / 554 |
| Compressor staging | Two-stage | 554 / 554 |
| Connected capability | No | 554 / 554 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS1+JMET12CS2N1AHRI reference: 217019195 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4014161 → |
CTU60C5XGS1+JMET12CS2N1+TXVAHRI reference: 217019197 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4014164 → |
CTF60D5CGS1+JME18D2SN1AHRI reference: 217019199 | 16.00 | 8.10 | 27000 | 2.30 | EPA 4014166 → |
CTU60D5XGS1+JME18D2SN1+TXVAHRI reference: 217019201 | 16.00 | 8.10 | 27000 | 2.30 | EPA 4014168 → |
CTF60C5CHS1+JME12C2SN1AHRI reference: 217019203 | 16.00 | 8.10 | 26400 | 2.36 | EPA 4014170 → |
CTF60C5CHS1+JME16C2SN1AHRI reference: 217019205 | 16.00 | 8.10 | 26800 | 2.36 | EPA 4014172 → |
CTF60C5CHS1+JMET12CS2N1AHRI reference: 217019207 | 16.00 | 8.10 | 26400 | 2.34 | EPA 4014174 → |
CTM60D5CHS1+JMET18DS2N1AHRI reference: 217019209 | 16.00 | 8.10 | 26800 | 2.36 | EPA 4014176 → |
CTF60C5CGS1+JMC17C2SN1AHRI reference: 217019211 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4014178 → |
JHE48C5CG2SS1AHRI reference: 217016739 | 16.00 | 8.00 | 27200 | 2.10 | EPA 4014185 → |
CTF60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 217019277 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4014199 → |
CTF60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 217019279 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4014200 → |
CTF60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 217019281 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4014202 → |
CTU60C5XGS1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 217019283 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4014203 → |
CTM60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 217019285 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014205 → |
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217019287 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4014207 → |
CTF60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217019289 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4014209 → |
CTF60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217019291 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4014210 → |
CTU60C5XGS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 217019293 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4014214 → |
CTM60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 217019295 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014215 → |