Coleman / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 21701914916.008.10268002.38EPA 4014117 →
JHC60C5CH2SS1AHRI reference: 21701915116.008.10270002.36EPA 4014119 →
CTM60C5CHS1+JMET12CS2N1AHRI reference: 21701915316.008.10264002.34EPA 4014121 →
CTM60C5CHS1+JME12C2SN1AHRI reference: 21701915516.008.10264002.36EPA 4014123 →
CTM60C5CHS1+JMVT17CC2N1AHRI reference: 21701915716.008.10266002.36EPA 4014125 →
CTF60C5CGS1+JMVT17CC2N1AHRI reference: 21701915916.008.10272002.28EPA 4014126 →
CTU60C5XGS1+JMVT17CC2N1+TXVAHRI reference: 21701916116.008.10272002.28EPA 4014129 →
CTF60D5CGS1+JMC20D2SN1AHRI reference: 21701916316.008.10272002.30EPA 4014131 →
CTU60D5XGS1+JMC20D2SN1+TXVAHRI reference: 21701916516.008.10272002.30EPA 4014133 →
CTM60D5CHS1+JMVT20DC2N1AHRI reference: 21701916716.008.10270002.38EPA 4014135 →
CTF60C5CGS1+JME12C2SN1AHRI reference: 21701916916.008.10268002.26EPA 4014137 →
CTU60C5XGS1+JME12C2SN1+TXVAHRI reference: 21701917116.008.10268002.26EPA 4014139 →
CTU60C5XGS1+JME16C2SN1+TXVAHRI reference: 21701917516.008.10272002.28EPA 4014140 →
CTF60C5CGS1+JME16C2SN1AHRI reference: 21701917316.008.10272002.28EPA 4014142 →
CTM60C5CHS1+JMC16C2SN1AHRI reference: 21701918116.008.10270002.36EPA 4014148 →
CTF60C5CHS1+JMVT16CC2N1AHRI reference: 21701918316.008.10270002.36EPA 4014150 →
JHE60D5CH2SS1AHRI reference: 21701918716.008.10270002.38EPA 4014152 →
CTM60D5CHS1+JME18D2SN1AHRI reference: 21701918916.008.10268002.38EPA 4014154 →
CTF60C5CGS1+JMET16CS2N1AHRI reference: 21701919116.008.10274002.26EPA 4014157 →
CTU60C5XGS1+JMET16CS2N1+TXVAHRI reference: 21701919316.008.10274002.26EPA 4014159 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.