Coleman / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 9

370 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 370 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16370 / 370
EER2 · BTU/Wh11–12370 / 370
HSPF2 · BTU/Wh7.8–8.1370 / 370
Cooling capacity · BTU/h44,500–48,000370 / 370
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000370 / 370
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400370 / 370
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200370 / 370
COP at 5°F / −15°C2.1–2.42370 / 370
Equipment / loop typeHP - Split System370 / 370
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)370 / 370
Compressor stagingTwo-stage370 / 370
Connected capabilityNo370 / 370

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678583215.207.80258002.20EPA 4572148
CTM60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678581715.207.80258002.26EPA 4572153
CTU60C5XGS1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21678580215.207.80254002.24EPA 4572158
CTF60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678578715.207.80254002.24EPA 4572163
CTM60D5CGS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678521315.207.80256002.28EPA 4572168
CTF60C5CHS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678500215.207.80262002.36EPA 4572173
CTM60C5CGS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678445915.207.80258002.26EPA 4572178
CTU60D5XGS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21678424115.207.80254002.24EPA 4572183
CTF60D5CGS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678422615.207.80254002.24EPA 4572188
CTM60C5CGS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21678377315.207.80258002.26EPA 4572193
CTM60C5CHS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21678361515.208.00260002.40EPA 4572208
CTM60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678345615.207.80256002.28EPA 4572213
CTF60C5CHS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21678234315.207.80260002.36EPA 4572223
CTM60C5CGS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21643768615.207.80254002.28EPA 4572228
CTM60C5CGS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21643765115.207.80260002.26EPA 4572233
CTU60D5XGS1+TXV+ furnace: Z9ET120D20SMPS1AHRI reference: 21637701915.207.80258002.26EPA 4572234
CTF60D5CGS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21637698915.207.80258002.26EPA 4572236
CTU60C5XGS1+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21574312015.207.80260002.26EPA 4572244
CTF60C5CGS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21574310115.207.80260002.26EPA 4572246
CTU60C5XGS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21480810115.207.80258002.20EPA 4572283

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →