XH548E2S11
LX SERIES · source records, page 8
370 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 370 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 370 / 370 |
| EER2 · BTU/Wh | 11–12 | 370 / 370 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 370 / 370 |
| Cooling capacity · BTU/h | 44,500–48,000 | 370 / 370 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 370 / 370 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 370 / 370 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 370 / 370 |
| COP at 5°F / −15°C | 2.1–2.42 | 370 / 370 |
| Equipment / loop type | HP - Split System | 370 / 370 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 370 / 370 |
| Compressor staging | Two-stage | 370 / 370 |
| Connected capability | No | 370 / 370 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60D5XHS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 216785047 | 15.20 | 8.10 | 26600 | 2.38 | EPA 4047093 → |
CTM60C5CHS1+ furnace: Z8ES120C20LMPS1AHRI reference: 216786498 | 15.20 | 8.10 | 26200 | 2.38 | EPA 4047098 → |
CTM60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 214605454 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570765 → |
CTM60C5CGS1+JMET16CS2N1AHRI reference: 214429364 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570774 → |
CTM60C5CGS1+JMC16C2SN1AHRI reference: 214429103 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570789 → |
CTF60C5CGS1+JMET16CS2N1AHRI reference: 214428898 | 15.20 | 7.80 | 25200 | 2.24 | EPA 4570794 → |
CTM60D5CGS1+JMET18DS2N1AHRI reference: 214427348 | 15.20 | 7.80 | 25400 | 2.28 | EPA 4570809 → |
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445017 | 15.20 | 7.80 | 26200 | 2.38 | EPA 4571130 → |
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445015 | 15.20 | 7.80 | 26200 | 2.38 | EPA 4571132 → |
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445012 | 15.20 | 7.80 | 26400 | 2.40 | EPA 4571135 → |
CTU60C5XGS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 217445008 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4571138 → |
CTF60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445007 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4571139 → |
CTM60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445001 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4571140 → |
CTU60C5XGS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 217445000 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4571141 → |
CTF60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217444999 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4571142 → |
CTM60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217444998 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4571143 → |
CTM60C5CGS1+ furnace: Z8ES100C16LMPS1AHRI reference: 216786289 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4572128 → |
CTF60C5CHS1+ furnace: Z8ES080C16LMPS1AHRI reference: 216786050 | 15.20 | 7.80 | 26200 | 2.36 | EPA 4572133 → |
CTF60C5CHS1+ furnace: Z8ES100C16LMPS1AHRI reference: 216786035 | 15.20 | 7.80 | 26000 | 2.38 | EPA 4572138 → |
CTU60C5XGS1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 216785846 | 15.20 | 7.80 | 25800 | 2.20 | EPA 4572143 → |