Coleman / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 9

275 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16275 / 275
EER2 · BTU/Wh10–12275 / 275
HSPF2 · BTU/Wh7.8–8.1275 / 275
Cooling capacity · BTU/h32,400–35,000275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000275 / 275
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400275 / 275
COP at 5°F / −15°C2–2.44275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingTwo-stage275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48D5CFS2+JMC20D2SN1AHRI reference: 21851936615.208.10177002.44EPA 4642764
CTM48D5CFS2+JMVT20DC2N1AHRI reference: 21851936215.208.10177002.44EPA 4642768
CTU48C5XFS2+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21851935815.208.10177002.42EPA 4642772
CTF48C5CFS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21851935415.208.10177002.42EPA 4642776
CTU48C5XFS2+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21851935015.208.10178002.40EPA 4642780
CTF48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21851934615.208.10178002.40EPA 4642784
CTU48C5XFS2+TXV+ furnace: TL9E080C16UH11AHRI reference: 21851932615.207.80176002.00EPA 4642804
CTF48C5CFS2+ furnace: TL9E080C16UH11AHRI reference: 21851932215.207.80176002.00EPA 4642808
CTU48C5XFS2+JMVT16CC2N1+TXVAHRI reference: 21851927815.208.10175002.00EPA 4642812
CTF48C5CFS2+JMVT16CC2N1AHRI reference: 21851927415.208.10175002.00EPA 4642816
CTU48C5XFS2+JMVT17CC2N1+TXVAHRI reference: 21851927015.208.10172002.00EPA 4642820
CTF48C5CFS2+JMVT17CC2N1AHRI reference: 21851926615.208.10172002.00EPA 4642824
CTU48C5XFS2+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21851926215.208.10175002.00EPA 4642828
CTU48C5XFS2+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 21851925815.208.10175002.00EPA 4642832
CTF48C5CFS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21851925415.208.10175002.00EPA 4642836
CTF48C5CFS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21851925015.208.10175002.00EPA 4642840
CTU48C5XFS2+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21851924615.208.10176002.00EPA 4642844
CTU48C5XFS2+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21851924215.208.10176002.00EPA 4642848
CTF48C5CFS2+ furnace: Z8ES080C20LMPS1AHRI reference: 21851923815.208.10176002.00EPA 4642852
CTF48C5CFS2+ furnace: Z8ES080C20SMPS1AHRI reference: 21851923415.208.10176002.00EPA 4642856

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →