Coleman / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 10

275 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16275 / 275
EER2 · BTU/Wh10–12275 / 275
HSPF2 · BTU/Wh7.8–8.1275 / 275
Cooling capacity · BTU/h32,400–35,000275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000275 / 275
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400275 / 275
COP at 5°F / −15°C2–2.44275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingTwo-stage275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU48C5XFS2+TXV+ furnace: TL8E100C20UH11AHRI reference: 21851923015.207.80173002.00EPA 4642860 →
CTF48C5CFS2+ furnace: TL8E100C20UH11AHRI reference: 21851922615.207.80173002.00EPA 4642864 →
CTU48C5XFS2+TXV+ furnace: Z9ES080C16SMPS1AHRI reference: 21851921415.207.80172002.00EPA 4642868 →
CTF48C5CFS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21851921015.207.80172002.00EPA 4642872 →
CTU48C5XFS2+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21851920615.208.10178002.00EPA 4642876 →
CTF48C5CFS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21851920215.208.10178002.00EPA 4642880 →
CTU48C5XFS2+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21851918215.208.10174002.00EPA 4642884 →
CTU48C5XFS2+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21851917815.208.10174002.00EPA 4642888 →
CTF48C5CFS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21851917415.208.10174002.00EPA 4642892 →
CTF48C5CFS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21851917015.208.10174002.00EPA 4642896 →
CTU48C5XFS2+JMC17C2SN1+TXVAHRI reference: 21851916615.208.10173002.00EPA 4642900 →
CTF48C5CFS2+JMC17C2SN1AHRI reference: 21851916215.208.10173002.00EPA 4642904 →
CTU48C5XFS2+JMC16C2SN1+TXVAHRI reference: 21851913815.208.10172002.00EPA 4642908 →
CTF48C5CFS2+JMC16C2SN1AHRI reference: 21851913415.208.10172002.00EPA 4642912 →
CTU48C5XFS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21851913015.208.10181002.38EPA 4642916 →
CTF48C5CFS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21851912615.208.10181002.38EPA 4642920 →
CTU48C5XFS2+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21851912215.208.10179002.40EPA 4642924 →
CTF48C5CFS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21851911815.208.10179002.40EPA 4642928 →
CTU48C5XFS2+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21851911415.208.10180002.38EPA 4642932 →
CTF48C5CFS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21851911015.208.10180002.38EPA 4642936 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →