Coleman / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 2

275 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16275 / 275
EER2 · BTU/Wh10–12275 / 275
HSPF2 · BTU/Wh7.8–8.1275 / 275
Cooling capacity · BTU/h32,400–35,000275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000275 / 275
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400275 / 275
COP at 5°F / −15°C2–2.44275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingTwo-stage275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+JMVT17CC2N1AHRI reference: 21443194815.208.10177002.44EPA 3558824
CTM36C5CDS1+JMVT16CC2N1AHRI reference: 21443197915.208.10176002.44EPA 3558827
CTF48C5CFS1+JMET12CS2N1AHRI reference: 21443150115.208.10173002.00EPA 3558867
CTM48C5CFS1+ furnace: TL8E080C16UH11AHRI reference: 21443150615.207.80172002.00EPA 3558872
CTF48C5CFS1+ furnace: TL8E100C20UH11AHRI reference: 21443151615.207.80173002.00EPA 3558877
CTM36C5CDS1+JME16C2SN1AHRI reference: 21443153815.208.10176002.44EPA 3558882
JHC36C5CD2SS1AHRI reference: 21443154315.208.10171002.00EPA 3558887
CTM48C5CFS1+JME12C2SN1AHRI reference: 21443114215.208.10176002.42EPA 3558907
CTM48C5CFS1+JMET12CS2N1AHRI reference: 21443114715.208.10176002.42EPA 3558910
CTF48C5CFS1+JMET16CS2N1AHRI reference: 21443115215.208.10173002.00EPA 3558917
CTM48C5CFS1+JMET16CS2N1AHRI reference: 21443115715.208.10176002.42EPA 3558922
CTM48C5CFS1+JME16C2SN1AHRI reference: 21443116215.208.10175002.42EPA 3558928
CTM48C5CFS1+JMC16C2SN1AHRI reference: 21443116715.208.10175002.42EPA 3558964
CTM48C5CFS1+ furnace: TL8E100C20UH11AHRI reference: 21443117215.208.10173002.00EPA 3558969
CTF48C5CFS1+JMC16C2SN1AHRI reference: 21443117715.208.10172002.00EPA 3558974
CTF48C5CFS1+JMC17C2SN1AHRI reference: 21443119415.208.10173002.00EPA 3558980
CTM48C5CFS1+JMC17C2SN1AHRI reference: 21443119915.208.10175002.44EPA 3558984
CTF48C5CFS1+JME12C2SN1AHRI reference: 21443120415.208.10173002.00EPA 3558990
CTF48C5CFS1+JME16C2SN1AHRI reference: 21443120915.208.10174002.00EPA 3558994
CTF36C5CDS1+JMVT17CC2N1AHRI reference: 21442887815.208.10172002.00EPA 3559079