Coleman / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES

275 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16275 / 275
EER2 · BTU/Wh10–12275 / 275
HSPF2 · BTU/Wh7.8–8.1275 / 275
Cooling capacity · BTU/h32,400–35,000275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000275 / 275
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400275 / 275
COP at 5°F / −15°C2–2.44275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingTwo-stage275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744498616.008.10180002.40EPA 4045138
CTF48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744498816.008.10180002.40EPA 4045139
CTU48C5XFS1+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 21744498916.008.10180002.40EPA 4045140
CTM48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744498716.008.10179002.40EPA 4045141
CTU48C5XFS1+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 21744499116.008.10181002.38EPA 4045143
CTF48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744499016.008.10181002.38EPA 4045144
CTU48C5XFS2+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 21851934216.008.10181002.38EPA 4642788
CTF48C5CFS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21851933816.008.10181002.38EPA 4642792
CTU48C5XFS2+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 21851933416.008.10180002.40EPA 4642796
CTF48C5CFS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21851933016.008.10180002.40EPA 4642800
CTM48C5CFS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21851892416.008.10179002.40EPA 4643036
CTM48C5CFS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21851892016.008.10180002.40EPA 4643040
CTM48C5CFS1+JMVT17CC2N1AHRI reference: 21442564215.208.10175002.44EPA 3558347
CTM48C5CFS1+JMVT16CC2N1AHRI reference: 21442565115.208.10175002.42EPA 3558352
CTF48C5CFS1+JMVT17CC2N1AHRI reference: 21442566215.208.10172002.00EPA 3558357
CTF48C5CFS1+JMVT16CC2N1AHRI reference: 21442567115.208.10175002.00EPA 3558362
CTF36C5CDS1+JMVT16CC2N1AHRI reference: 21442740915.208.10174002.00EPA 3558560
JHE42C5CF2SS1AHRI reference: 21442562215.208.10173002.00EPA 3558806
JHC42C5CF2SS1AHRI reference: 21442563215.208.10175002.00EPA 3558811
CTM36C5CDS1+JMC16C2SN1AHRI reference: 21443193015.208.10176002.44EPA 3558822

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →