Coleman / AIR-SOURCE HEAT PUMP

XH518E2S11

LX SERIES · source records, page 3

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity17,000–18,600BTU/h

Each efficiency range summarizes published EPA records for XH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16249 / 249
EER2 · BTU/Wh12–12.5249 / 249
HSPF2 · BTU/Wh7.8249 / 249
Cooling capacity · BTU/h17,000–18,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300249 / 249
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100249 / 249
COP at 5°F / −15°C2.26–2.34249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU24A5XBS1+TXV+ furnace: TMLV060A12MP12AHRI reference: 21582055415.207.8089002.26EPA 3712613
CTU24A5XBS1+TXV+ furnace: TPLC060A12MP13AHRI reference: 21582055915.207.8089002.26EPA 3712618
CTU24A5XBS1+TXV+ furnace: CPLC060A12MP13AHRI reference: 21582056415.207.8089002.26EPA 3712623
CTF24B5ABS1+ furnace: Z9ET080B12SMPS1AHRI reference: 21582058115.207.8090002.28EPA 3712626
CTF30B5ACS1+ furnace: Z8ES100B12SMPS1AHRI reference: 21582095115.207.8088002.30EPA 3712666
CTU30B5XCS1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21582095615.207.8088002.30EPA 3712672
CTM30B5ACS1+ furnace: Z8ES080B12SMPS1AHRI reference: 21582046715.207.8088002.30EPA 3712676
CTF30B5ACS1+ furnace: TL9E060B12UH11AHRI reference: 21582047215.207.8091002.26EPA 3712681
CTU30B5XCS1+TXV+ furnace: TL9E060B12UH11AHRI reference: 21582047715.207.8091002.26EPA 3712686
CTM30B5ACS1+ furnace: TM8E100B12MP11AHRI reference: 21582048715.207.8091002.28EPA 3712691
CTM30B5ACS1+ furnace: TMLE100B12MP11AHRI reference: 21582049215.207.8091002.28EPA 3712696
CTF30B5ACS1+ furnace: Z8ES080B12SMPS1AHRI reference: 21582049715.207.8088002.30EPA 3712701
CTU30B5XCS1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21582050215.207.8088002.30EPA 3712706
CTM24A5ABS1+ furnace: Z8ET060A12LMPS1AHRI reference: 21582097615.207.8088002.26EPA 3712711
CTF24A5ABS1+ furnace: Z8ES040A12SMPS1AHRI reference: 21582098615.207.8088002.28EPA 3712716
CTU24A5XBS1+TXV+ furnace: Z8ES040A12SMPS1AHRI reference: 21582099115.207.8088002.28EPA 3712722
CTF24B5ABS1+ furnace: TMLE080B12MP11AHRI reference: 21582044715.207.8091002.26EPA 3712726
CTM24A5ABS1+ furnace: Z8ES060A12SMPS1AHRI reference: 21582052215.207.8090002.28EPA 3712731
CTF24A5ABS1+ furnace: TM8V060A12MP12AHRI reference: 21582053215.207.8089002.26EPA 3712736
CTF30B5ACS1+ furnace: TM8E080B12MP11AHRI reference: 21582017915.207.8088002.28EPA 3712751