Coleman / AIR-SOURCE HEAT PUMP

XH518E2S11

LX SERIES · source records, page 2

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity17,000–18,600BTU/h

Each efficiency range summarizes published EPA records for XH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16249 / 249
EER2 · BTU/Wh12–12.5249 / 249
HSPF2 · BTU/Wh7.8249 / 249
Cooling capacity · BTU/h17,000–18,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300249 / 249
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100249 / 249
COP at 5°F / −15°C2.26–2.34249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU30B5XCS1+JMC12B2SN1+TXVAHRI reference: 21574034215.207.8089002.34EPA 3652699 →
CTF24B5ABS1+JMET08BS2N1AHRI reference: 21574034715.207.8089002.32EPA 3652704 →
CTF24B5ABS1+JMC12B2SN1AHRI reference: 21574035215.207.8089002.32EPA 3652709 →
CTF30B5ACS1+JMET08BS2N1AHRI reference: 21574035715.207.8090002.34EPA 3652714 →
CTM30B5ACS1+JMC12B2SN1AHRI reference: 21574036315.207.8090002.32EPA 3652720 →
CTM30B5ACS1+JME12B2SN1AHRI reference: 21574036815.207.8089002.34EPA 3652725 →
CTF30B5ACS1+JME12B2SN1AHRI reference: 21574037315.207.8089002.34EPA 3652731 →
CTU30B5XCS1+JMET08BS2N1+TXVAHRI reference: 21574037815.207.8090002.34EPA 3652738 →
CTF24B5ABS1+JME08B2SN1AHRI reference: 21574039015.207.8088002.32EPA 3652741 →
CTM24B5ABS1+JME12B2SN1AHRI reference: 21574038515.207.8088002.32EPA 3652749 →
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 21574039515.207.8089002.34EPA 3652753 →
CTF30B5ACS1+JME08B2SN1AHRI reference: 21574040015.207.8089002.34EPA 3652757 →
CTM30B5ACS1+JMET08BS2N1AHRI reference: 21574040715.207.8089002.32EPA 3652765 →
CTM24B5ABS1+JMET12BS2N1AHRI reference: 21574041215.207.8088002.30EPA 3652768 →
CTM30B5ACS1+JMET12BS2N1AHRI reference: 21574041715.207.8088002.30EPA 3652774 →
CTU30B5XCS1+JME08B2SN1+TXVAHRI reference: 21574042215.207.8089002.34EPA 3652778 →
CTF24A5ABS1+ furnace: TMLV060A12MP12AHRI reference: 21582053715.207.8089002.26EPA 3712596 →
CTF24A5ABS1+ furnace: TPLC060A12MP13AHRI reference: 21582054215.207.8089002.26EPA 3712601 →
CTF24A5ABS1+ furnace: CPLC060A12MP13AHRI reference: 21582054715.207.8089002.26EPA 3712606 →
CTU24A5XBS1+TXV+ furnace: TM8V060A12MP12AHRI reference: 21582054915.207.8089002.26EPA 3712608 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →